STATUS INDICATORS
When the following indicators light up or blink on the operation panel or the following alphanumeric codes
appear in the display, solve the problem immediately referring to both the table below and the relevant page.
Be sure to use only genuine SHARP parts and supplies.
Developer
replacement
required indicator
Toner cartridge
replacement
required indicator
Misfeed indicator
Maintenance
indicator
SPF misfeed
indicator
Power save indicator is
steadily lit.
The paper tray indicator is
blinking.
"CH" is blinking in the
display.
"CH" is steadily lit in the
display.
"P" is blinking in the display.
A letter and a number appear
alternately.
A letter and a number appear
alternately.
30
Indication
Steadily
lit
Steadily
lit
Blinking
Blinking
Steadily
lit
Blinking
Cause and remedy
Developer is required. contact your authorised
service representative.
Replacement of Toner cartridge will be needed
soon. Prepare a new cartridge. (AR-152T)
Toner cartridge must be replaced. Replace it
with a new one. (AR-152T)
A misfeed has occurred. Remove the misfed
paper referring to the description of "MISFEED
REMOVAL".
The lower side cover may be open. If so, close it.
Service by an authorised SHARP service
technician is required.
An original misfeed has occurred in the SPF.
Remove the misfed originals referring to the
description of "E: Misfeed in the SPF (AR-153EN)".
The unit is in the preheat mode. Press any key to
cancel the preheat mode.
The unit is in the auto power shut-off mode.
Press the start (
) key to cancel the auto power
shut-off mode.
The paper tray is not installed properly. Push the
tray into the unit securely.
The toner cartridge is not installed. Check if the
cartridge is installed. If "CH" is blinking even if a
cartridge is installed properly, contact your
SHARP service centre immediately.
Side cover is open. Close the side cover
securely by pressing the round projections near
the side cover open button.
The paper tray or multi-bypass tray is empty.
Load paper.
A misfeed has occurred in the paper tray, single
bypass or multi-bypass tray. Remove the misfed
paper.
Paper tray is not securely installed. Push the tray
in securely.
The scan head locking switch is locked. Unlock
the scan head locking switch and turn the power
switch off/on.
The unit will not function. Turn the power switch
off and then switch it on, and if there is again an
error, remove the power cord from the outlet,
and contact your authorized service
representative.