Alarm
Fault
Core probe not inserted in the
E29
food
E80
1 Chamber inverter anomaly
E81
2 Chamber inverter anomaly
1 chamber combustion control
E82
anomaly
2 chamber combustion control
E83
anomaly
1 chamber incorrect configura-
E84
tion
2 chamber incorrect configura-
E85
tion
"Cleaning timer" timeout warn-
W01
ing
Chamber
W02
check warning
Cleaning was interrupted by
WARNING!
means of the START/STOP
cleaning
interrupted
button
IT
GB
ATTENTION!
call the engi-
A year has elapsed since the
DE
neer to check
last CO and CO2 fumes check
the CO2 and
FR
CO emissons
ES
English
Remedy
Insert the core probe
Inform the after-sales service
Inform the after-sales service
Inform the after-sales service
Inform the after-sales service
Inform the after-sales service
Inform the after-sales service
Carry out cleaning before timer
timeout.
Check the chamber limescale
limescale
quantity
quantity and descale if neces-
sary.
Restart cleaning or carry out an
emergency rinse.
Inform the after-sales service
- 52 -
Notes
The oven's functions are ena-
bled so cooking cycles can be
carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
The oven's functions are disa-
bled so no cooking cycles can
be carried out
It is possible to carry out a
cooking cycle when residual
time has elapsed
It is not possible to carry out
cooking cycles until a com-
plete washing cycle or emer-
gency rinse cycle has been
carried out
To clean the parts inside the
technical compartment (be-
hind the door) it is necessary
to use abrasion and cut resist-
ant gloves
Use and installation manual