COUNTER BALANCED DOORS USING THE "SCUTI" OPERATOR
GENERAL INFORMATION
The Scuti kit consists of a self contained power mono-bloc,
with installation and functioning accessories.
The power mono-bloc consists of two parts:
A) the top part contains the electric motor and the pump
immersed in oil bath. The top cover contains the cable entry
and breather/filler cap;
B) the lower section contains the thrusting jack, whose rack
provides power to move the pinion of the output drive shaft.
The body of the jack is closed off top and bottom by plates. The
hydraulic lock, emergency release and pressure adjusting
function are inserted in these plates. The valve block and
motor - pump block are fixed on the middle plate.
The unit dimensions are shown in Fig. 1 which also indicates
the position and orientation of the unit on the door.
The Scuti is manufactured in anodised aluminium and
can be fitted to existing one-piece or folding vertical
track doors.
MODELS AND VERSIONS
The Scuti unit can be supplied with or without hydraulic lock. Non-locking units require an electric lock. In any case the
unit has an emergency release device: when activated the door can be easily opened and closed manually.
The unit is manufactured with two manual release device positions, one for use on the inside and the other for use from
the outside using a personalised key.
The outside release key is necessary if the room does not have a separate entrance door.
TECHNICAL DATA
Electric motor :
- thermal switch 130°
- two-directional rotation
- absorbed current 1.2 A
- absorbed power 220 W
- rotation speed 1400 rpm
Jack cylinder:
- bore 70 mm
- stroke 70 mm
- rotation 200°
Hydraulic pump capacities:
Capacity (l.)
0.5
Pressure (Bar)
50
Cod. 67410030
All manuals and user guides at all-guides.com
SEA S.r.l. Zona Ind.le S. Atto Teramo Italia
Sito Internet:
E-mail: seacom@seateam.com (Uff. Commerciale)
seatec@seateam.com (Uff. Tecnico)
INSTALLATION
SCUTI
INSTALLATION INSTRUCTIONS FOR AUTOMATING
0.75
50
Rev. 01 del 05/1999
http://www.seateam.com
Breather - Filler cap
Fig. 1
Oil level
By-pass
Manual
valve
release
Emergency release