List Of Parameters - Sime Brava One 40 BF Manuel Pour L'installation Et L'entretien

Masquer les pouces Voir aussi pour Brava One 40 BF:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

– press the button
>
to scroll up the list of parameters and then
<
to scroll down the list
holding the buttons
NOTE:
scrolling movement.
– once the required parameter has been reached, press the
button
o
for approximately 3 seconds to confirm and access
the set value which will then flash and can then be modified
– to modify the value in the permitted range, press the buttons
>
to increase it or
<
to decrease it
– once the required value has been reached, press the button
o
to confirm.
3.4

List of parameters

Type
No.
Description
tS
0.1
Index showing boiler power in kW
tS
0.2
Hydraulic configuration
tS
0.3
Gas Type Configuration
tS
0.4
Combustion configuration
tS
0.7
Ignition power
tS
0.8
External sensor value correction
tS
1.0
Boiler Antifreeze Threshold
External Sensor Antifreeze Threshold
tS
1.1
-- = Disabled
tS
1.2
Heating Curve Incline
tS
1.3
Minimum Heating Temperature Adjustment
tS
1.4
Maximum Heating Temperature Adjustment
tS
1.5
Maximum power heating
tS
1.6
Heating Post-Circulation Time
tS
1.7
Heating Pump Activation Delay
tS
1.8
Re-ignition Delay
tS
1.9
Domestic Hot Water Modulation with Flow meter
tS
2.0
Maximum power domestic hot water
Minimum power heating/domestic hot water
tS
2.1
(premixed)
tS
2.2
Domestic hot water preheating enabling
tS
2.5
Internal parameter (no change)
tS
2.6
Zone Valve / Pump Relaunch Delay
22
>
or
<
increases the speed of the
DOMESTIC HOT WATER - HEATING
When all the parameter modifications have been made, exit the
parameter menu by pressing and holding down the buttons
and
o
at the same time
initial screen is displayed.
Range
CONFIGURATION
2 = 40
0 = rapid
1 = storage tank with thermostat or
heating only
2 = hot water tank with sensor
3 = bithermic
4=instant with solar power input
0 = G20
1 = G31
0 = sealed chamber with combustion
control
1 = open chamber with smoke
thermostat
2 = low NOx
0 .. 40
-5 .. +5
0 .. +10
-9 .. +5
0 .. 80
20 .. Par tS 1.4
Par tS 1.3 .. 80
0 .. 100
0 .. 99
0 .. 60
0 .. 60
0 = Disabled
1 = Enabled
0 .. 100
0 .. 100
0 = OFF
1 = ON
-
0 .. 99
for approximately 5 seconds until the
U/M
Step
Default
-
-
-
1
-
1
-
1
-
1
°C
1
°C
1
°C
1
-
1
°C
1
°C
1
%
1
seconds
1
x 10
seconds
1
x 10
Min
1
-
1
%
1
%
1
-
1
-
-
Min
1
EN
<
2
0
0 or 1
0
0
0
3
-2
20
20
80
100
3
0
3
1
100
0
0
0
1