2.4

Product description

The submersible pump with multi-vane impeller can be pur-
chased with or without float switch for level measurement.
Depending on the intended application, it is supplied with a
preassembled mains connection cable or a coded plug for
connection to the control unit.
The intake area of the GTF 1000 has an intake cage which
prevents coarse materials (> 10 mm ø) being drawn in. The
intake cage can be removed for deep extraction.
The stand of the GTF 1200 and GTF 1250 allows a free ball
passage of 30mm.
Item no.
Assemblies and functions
(1)
Intake cage
(2)
Spiral housing
(3)
Multi-vane impeller
(4)
Mains plug
(5)
Float switch
(6)
Pressure pipe connection
(7)
Position for vent
(8)
Hose adapter 1 1/4", 1 1/2" (GTF1000 only)
(9)
Stand (GTF1200, GTF 1250 only)
016-212_04