FINAL OPERATIONS
Before closing up the casing, check that the cable inlets are sealed to stop insects getting in and to prevent damp.
PAIRED OPERATION
Two connected operators are controlled with one command.
Electrical connections
Connect the two electronic boards with a UTP CAT 5 cable.
Fit an RSE card on both control boards, using the RSE_1 connector.
Connect up the electrics for the devices and accessories.
The devices and accessories must be connected to the control board which will be set as the MASTER.
For information on connecting the electrics for the devices and accessories, please see the "ELECTRICAL CONNECTIONS" section.
A B GND
A B GND
Programming
All programming operations described below must be performed only on the control board set as the MASTER.
Select the [Paired] system type when following the guided procedure, or configure the RSE_1 port to [Paired] mode.
After programming the MASTER operator in [Paired], the second operator automatically becomes SLAVE.
Saving users
All save user operations must be performed only on the control board set as the MASTER.
MASTER
RSE
UTP CAT 5
SLAVE
A B GND
A B GND
RSE