RIO PH T2
Associate one of the available functions with a wireless safety device.
Configuration
RIO safety devices
Command 2-7
Associate a command with the device connected to 2-7.
Configuration
Command inputs
Hold-to-run
With the function active, the operator stops moving (opening or closing) when the control device is released.
When the function is active, it excludes all other control devices.
Configuration
Functions
B1-B2 output
Configure the contact.
Configuration
Functions
Removing obstacles
If an obstacle is detected by the sensitive edge or by the amperometric sensor on the electronic board, movement is inverted to create a space sufficient to clear
the obstacle.
If this function is deactivated, the motion is inverted until the limit-switch is reached.
Configuration
Functions
Automatic closure
Set the time before automatic closure is activated, once the opening travel end point has been reached.
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
Configuration
Times
Automatic closing after partial opening
Set the time before automatic closure is activated, after a partial opening command has been performed.
The function does not work if any of the safety devices are triggered when an obstacle is detected, or after a complete stop, or during a power outage.
Do not deactivate the function [Automatic close].
Configuration
Times
RIO PH T2
Command 2-7
Hold-to-run
B1-B2 output
Removing obstacles
Automatic close
Automatic partial close
Disabled (Default)
P1 = Reopen while closing.
P2 = Reclose while opening.
P3 = Partial stop.
P4 = Obstacle standby.
P13 = Reopening during closure with immediate stop once the obstacle has been
removed, even with the gate not in motion.
Step-by-step (Default)
Sequential
Deactivated (Default)
On
Bistable
Monostable (Default)
The contact remains closed for 1 to 180 seconds.
Deactivated (Default)
On
Deactivated (Default)
From 1 to 180 seconds
Off
1 to 180 seconds (Default 10 seconds)