Establishing the travel end points with magnetic limit switches
* Only for BKV15AGE, BKV20AGE and BKV25AGE
A
Magnetic limit-switch tabs during closing
B
Magnetic limit-switch tabs during opening
To the left (Default)
Edit the parameter for the function [Opening direction].
The figures below show the limit switch installed with the operator on the left.
Open the gate.
Insert the magnetic opening limit-switch tab on the rack.
The tab magnet must be between 10 and 30 mm from the magnetic sensor.
~ 20
Fasten the support to the rack using the grub screws supplied.
The limit-switch tab magnet must be perpendicular to the magnetic sensor.
Fasten the limit-switch tab using the screw (supplied).
To the right