PRECAUTION
Risk of cutting due to sharp edges!
Threads, boreholes and pipe edges are
J
sharp and may lead to injuries.
• Wear safety gloves if required.
2.1 Definition of the warning notices
These installation and operating instructions show
warnings which are displayed by symbols. The symbols
are linked to signal words which define the seriousness
of the danger which arises from a situation. The warnings
are to be observed to avoid injuries to persons and
damage to property.
!
WARNING
WARNING indicates a possible dangerous
situation which may lead to death or
serious injury if the safety guidelines are not
observed.
!
PRECAUTION
PRECAUTION indicates a possible
dangerous situation which may lead to minor
or moderate injury if the safety guidelines
are not observed.
2.2 Correct use
Safety in operation is only guaranteed if the heat meter
installation set is used correctly.
The heat meter installation set allows the use of a heat
meter (length 110 mm / 130 mm, connection G
in "Regumat S / M3 – 180" DN 25 (2015) – product
assemblies with pump ball valve.
Any use of the heat meter installation set outside the
above applications will be considered as non-compliant
and misuse. Claims of any kind against the manufacturer
and/or his authorised representatives due to damages
caused by incorrect use cannot be accepted.
The observance of the installation and operating
instructions is part of the compliance terms.
6
3 Transport, storage and
packaging
3.1 Transport inspection
Upon receipt check delivery for any damages caused
during transit and for completeness.
Any damage must be reported immediately upon
receipt.
3.2 Extent of supply
– 1 x ball valve with heat meter temperature sensor
connection
– 2 x reducer G 1
thread
– 2 x reducer G 1 male thread x G
– 1 x collar nut G 1
– 5 x seal G 1
– 2 x seal G 1
– 2 x seal G
3.3 Storage
The heat meter installation set must only be stored
under the following conditions:
– Do not store in open air, keep dry and free from dust.
– Do not expose to aggressive fluids or heat sources.
– Protect from direct sunlight and mechanical agitation.
– Storage temperature: –20 °C up to +60 °C
– Max. relative humidity of air: 95 %
3.3 Packaging
Packaging material is to be disposed of environmentally
friendly.
/ G 1)

4 Technical data

3
4
For heat meters with a length of 110 mm
Connections:
2 x reducer G
meter
2 x reducer G 1
"Regumat" product assembly
For heat meters with a length of 130 mm
Connections:
2 x reducer G 1 female thread, flat sealing to the heat
meter and G 1
"Regumat" product assembly
4.1 Materials
Fittings
Handle
Seals
!
WARNING
Before starting work, make sure that the pipework
and components have cooled down and been
drained!
Before work commences, please ensure that all
electrical components (controllers, pumps etc.)
are disconnected from the power supply and are
protected against accidental restart!
male thread x G 1 female
1
2
3
4
1
2
1
2
3
4
female thread, flat sealing to the heat
3
4
male thread, flat sealing to the
1
2
male thread, flat sealing to the
1
2
Brass
PA 6.6
EPDM / KAUTASIT