Installation
Choosing installation equipment
Cut out the work surface according to the sizes shown in the drawing.
Leave a space of at least 5 cm around the hole for the purpose of installation and use.
Make sure the work surface is at least 30 mm thick. Please select a heat-resistant work
surface material to avoid extensive deformation due to the heat radiated by the hotplate.
As shown below:
L(mm)
W(mm)
590
520
Under all circumstances, make sure the induction hob is well ventilated and that the air inlet
and outlet are not blocked. Ensure the induction hob is in good working condition as shown
below.
Note: Leave a safety distance of at least 700 mm between the hotplate and the
cupboard above the hotplate. If over the hob a hood is installed, keep as
reference the distance indicated into the hood user manual.
H(mm)
D(mm)
60
55
A(mm)
B(mm)
560
490
17
X(mm)
50 min.