2.2 Accessories / Spare parts
Fig. 2
Item
1. Remote filter holder
2. Belt attachment
3. Polyester belt
4. Leather belt
4. Leather belt, Large
5. Half mask SR 900 S
5. Half mask SR 900 M
5. Half mask SR 900 L
6. Hose SR 951
7. Twin hose SR 952
2.3 Filter
You can identify the filter type by the colour
code on the filter. See the User instructions
for filters. Note that a particle filter provides
protection only against particles and a gas
filter provides protection only against gases/
vapours. A combined filter protects against
both gases/vapours and particles.
Item
• Particle filter P3 R, SR 510
• Gas filter A1, SR 217
• Gas filter A2, SR 218
• Gas filter AX, SR 298
• Gas filter ABE1, SR 315
• Gas filter ABE2, SR 294
• Gas filter K1, SR 316
• Gas filter K2, SR 295
• Gas filter ABEK1, SR 297
• Combined filter
ABEK1-Hg-P3 R, SR 299-2
3. Use
3.1 Assembly
• Detach the filter holder from half mask SR
900. Fig. 3.
• Remove the inhalation membrane from the
filter holder. Fig. 4. Save the membrane for
future use.
Fit the filter in the filter holder
• Check that you have selected the correct
filter. See the User instructions for filters.
• Check that the use-by date has not been
passed. The use-by date is valid provided
that the filter packaging is unopened.
24
• Fit the filter in the filter holder so that the
arrows on the filter point towards the filter
holder. Fig. 5.
Ordering No.
• Carefully check that the edge of the filter is
T01-3002
in the internal groove of the filter mounting
R01-3028
all around. Fig. 6, 7.
T01-3005
• Fit the pre-filter in the pre-filter holder and
R01-3006
press it into place on the filter. Fig. 8, 9.
T01-3006
H01-3012
When using both gas filter and particle filter,
H01-3112
the particle filter shall always be snapped onto
the gas filter and the gas filter shall always be
H01-3212
inserted in the filter holder. Press the filters
T01-3003
together with your fingers placed around
R01-3009
the outer edges of the filters until you hear a
click. Fig. 10.
Separating filter
• Place a coin between the lower lip of the
particle filter and the small tab moulded into
the side of the gas filter.
• Push firmly and twist the coin until the filters
separate. Fig. 11.
Remote filter holder SR 905
Ordering No.
• Assemble the belt in the belt attachment.
H02-1312
Fig. 12.
H02-2512
• Assemble the SR 905 to the belt attachment.
H02-2012
Two alternative. Fig 13, 14.
H02-2412
• Assemble the filter holder with filter onto the
H02-3212
SR 905. Fig. 15.
H02-3312
3.2 Inspection before use
H02-4212
H02-4312
• Check that the unit is complete, correctly
H02-5312
assembled and thoroughly cleaned.
• Check all parts. Replace if worn, broken, or
H02-6512
in other way defect. Fig. 16.
• Check that you have selected the right filter
and it has been installed properly. Fig. 16.
3.3 Putting the equipment on
• Take the SR 905 on and adjust the belt
so that the remote filter holder is firmly
and comfortably secured at the back of
your waist.
• Assemble the breathing hose into the half
mask. Fig. 17.
• Put on the half mask. See SR 900 User
instruction.
• Make sure that the breathing hose runs
along your back and is not twisted. Fig. 18.
• Rotate the belt around your waist so that
you reach the hose connection on SR 905.
• Assemble the breathing hose into SR 905.