Technical Assistance; Technical Description; Intended Use; Improper Use - Calpeda e-idos E-MPSM Serie Instructions Pour L'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
The Warranty will not be considered in the following
cases:
- Whenever the use of the device does not conform
to the instructions and information described in this
manual.
- In case of changes or variations made without
authorization of the manufacturer.
- In case of technical interventions executed by a non-
authorized personnel.
- In case of failing to carry out adequate maintenance.

1.5. Technical assistance

Any further information about the documentation,
technical assistance and spare parts, shall be
requested from: Calpeda S.p.A. (paragraph 1.2).

2. TECHNICAL DESCRIPTION

Close coupled submersible multistage pump with
integrated control, complete with integrated pressure
transducer for automatic control of starting/stopping of
the pump when utilization points are opened/closed.
For protection of the pump:
- against dry running;
- against the risk of operation without water at the inlet
(caused by a lack of water inflow in the inlet pipe
under positive suction head, by a non-immersed
suction pipe, by excessive suction lift or by air
entering the suction pipe);
External jacket in stainless steel AISI 304 and stages
Noryl.
Hydraulics are located below the motor with the motor
cooled by the pumped fluid. Safe operation is possible
with the motor only partially submerged.
Double shaft seal with interposed oil chamber.
The suction strainer prevents the ingress of solids with
diameter larger than 2mm.

2.1. Intended use

For water supply from wells, tanks or reservoirs.
For domestic use, for civil and industrial applications,
for garden use, irrigation and rain water harvesting
systems.
For clean water with a maximum temperature of 35 °C
and maximum sand content of 60 g/m3.
Minimum internal diameter of well: 140 mm.
- Minimum immersion depth: 100 mm.
- Maximum submersion depth: 20 m (with suitable
cable length).

2.2. Improper use

The device is designed and built only for the purpose
described in paragraph 2.1.
Improper use of the device is forbidden, as is
use under conditions other than those indicated
in these instructions.
Improper use of the product reduces the safety and
the efficiency of the device, Calpeda shall not be
responsible for failure or accident due to improper use.
Do not use in ponds, tanks or swimming pools
or where people may enter or come into contact
with the water.
2.3. Marking
The following picture is a copy of the name-plate that is
on the external case of the pump.
E-MPSM Rev3 - Operating Instructions
1 Pump type
2 Delivery
3 Head
4 Rated motor power
5 Supply voltage
1
6 Rated current
2
7 Notes
3
8 Frequency
4
9 Operation Duty
5
10 Insulation class
6
11 Weight
7
12 Power factor
13 Rotation speed rpm
14 Protection
15 AAAA Year of
manufacture
15 XXXX Serial
number
16 Certifications

3. TECHNICAL FEATURES

3.1. Technical data

Dimensions and weight (see technical catalogue).
Nominal speed 2900 rpm
Pump protection IP X8
Control box protection IP X4
Supply voltage / Frequency:
230V ± 10% 50 Hz
Check that the mains frequency
correspond to the electrical characteristics shown on
the indicator plate.
The electric data marked on the label are referred to
the nominal power of the motor.
Sound pressure at minimum immersion depth: < 70 dB
(A).
Max. starts per hour: 120 at regular intervals.
Maximum permissible pressure in the pump casing: 80
m (8 bar).
The max. inlet water pressure: PN (Pa) - Hmax (Pa)
[1bar = 100.000 Pa].
3.2. Pushbuttons functions
The user interface is made by a 6 pushbuttons
keyboard. Every pushbutton has a specific function
described in the following table.
Through this button you can start the pump.
Through this button you can stop the pump.
Example plate pump
Montorso (VI) Italy IT 00142630243
Made in Italy
XXXXXXX
AAAAXXXXX
Q min/max X/X m
/h
3
H max/min X/X m
IP XX
X kW (XHp)
n XXXX/min
S.F.
cosø X
220 /380Y V3~50Hz
X/X A
S1 l.cl. X X kg
XXXXXXXX
8
9 10
and voltage
Page 11 / 72
16
15
EN
14
13
12
11

Publicité

Table des Matières
loading

Table des Matières