Scope Of Delivery; Device Description; Bluetooth; General Information - Benning CM 10-1 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

In order to prevent danger
-
do not touch the bare contact tips of the measuring leads,
-
plug the measuring leads into the correspondingly marked
measuring sockets of the multimeter and check them for
tight fit.
Maintenance:
Do not open the multimeter, because it contains no components
which can be repaired by the user. Repair and service must be
carried out by qualified personnel only!
Cleaning:
Regularly wipe the housing by means of a dry cloth and clean-
ing agent. Do not use any polishing agents or solvents!
3.

Scope of delivery

The scope of delivery of the BENNING CM 10-1 comprises:
3.1 One BENNING CM 10-1
3.2 Two safety measuring lead, red/ black (L = 1.4 m) (part no. 044145)
3.3 One compact protection carrying case
3.4 Two 1.5 V batteries (type AA/ IEC LR6) for initial assembly is integrated
into the device
3.5 One operating manual
Note on optional accessory:
-
Flexible AC current transformer BENNING CFlex 1 (part no. 044068)
Alternating current ranges: 30 A/ 300A/ 3000 A
Parts subject to wear:
-
The BENNING CM 10-1 is supplied by means of two integrated 1.5 V batter-
ies (AA/ IEC LR6).
-
With the protective caps being attached, the safety measuring leads men-
tioned above (tested accessories, item no. 044145) comply with CAT III
1000 V/CAT IV 600 V and are approved for a current of 10 A.
4.

Device description

See figure 1:
The display and operating elements shown in figure 1 are designated as follows:
1 Measuring clamp, for clamping on the single-wire live conductor,
2 Bulge for current clamp, protects against contact with conductor,
3 LED (red) for voltage indicator and continuity test
4 Opening lever, for opening and closing the current clamp, for activation of
the measuring point illumination
5 HOLD/ZERO key, measured value storage respectively ZERO for null bal-
ance (ADC)
6 Rotary switch, for selecting the measuring function,

7 Bluetooth

®
8 HFR key, to enable the high-frequency suppression (low-pass filter), or IN-
RUSH function
9 MIN/MAX-key, storage of highest and lowest measurement value, resp. Volt-
sense function
J MODE key (blue), for selecting the measuring function/secondary function,
resp. display illumination
K Digital display, for the measurement value and display for overrange indica-
tion
L Polarity indication,
M Battery condition indicator,
N COM jack, common jack for voltage/ resistance/ frequency/ capacity mea-
surements, continuity tests and diode tests
O Jack + (positive
This is what the automatic polarity indication for DC current and DC voltage refers to
1)
5.
General information of the digital current clamp multimeter

5.1 General information

5.1.1
The digital display K is designed as a 4 digit liquid crystal indicator with
15 mm digit height and decimal point. The highest value displayed is
6000.
11/ 2019
Device front
key, for activation of the Bluetooth
), for V, µA, Ω, Hz, μF
1
BENNING CM 10–1
interface, resp. LOG function
®
24