Electrical Specifications - Benning CM 10-1 Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

7.

Electrical specifications

Note: The measuring precision is specified as the sum of
- a relative fraction of the measured value and
- a number of digits (counting steps of the least significant digit).
This specified measuring precision is valid for temperatures in the range from
18 °C to 28 °C and relative humidity less than 80 %. The stated accuracy is
specified for 1 % to 100 % of the final measuring range value.
Additional specifications for AC functions:
The measuring value is gained and indicated as effective value (True RMS, AC
coupling). In case of non-sinusoidal curves, the indicating value becomes inaccu-
rate. Thus, an additional error occurs for the following crest factors:
crest factor from 1.0 to 2.0 additional error + 3.0 %
crest factor from 2.0 to 2.5 additional error + 5.0 %
crest factor from 2.5 to 3.0 additional error + 7.0 %
Maximum crest factor of the measuring signal:
crest faktor 3.0 @ 3000 digits
crest faktor 2.0 @ 4500 digits
crest faktor 1.5 @ 6000 digits
Measured values < 20 digits are set to 0 on the digital display K .
Square-wave signals are not specified.
HFR function (low-pass filter)
additional error for functions V
± 4 % with regard to the specified measuring accuracy (45 Hz to 200 Hz)
Limiting frequency fg (- 3 dB): 800 Hz
7.1 Voltage ranges (V AC, V DC)
Function
Measuring
V AC
600.0 mV
V DC
Overload protection:
Input resistance: DC:
7.2 Voltage ranges (LoZ, AutoV)
Function
Measuring
LoZ
Overload protection:
Input resistance:
Frequency range:
7.3 Current ranges (A
Function
Measuring
A AC
[1] [2]
A DC
[1]
Measured values below < 5 A, plus 10 digits
[1]
Measured values > 1000 A, plus 0.5 % digits
Frequency > 100 Hz, plus 1 %
[2]
Overload protection:
Frequency range (sine): 45 Hz ~ 400 Hz (≤ 1000 A)
Positioning error:
11/ 2019
AC
Resolution
range
600.0 V
0.1 V
1000 V
1 V
0.1 mV
600.0 V
0.1 V
1000 V
1 V
1000 V
10 MΩ, AC: 10 MΩ II < 100 pF
Resolution
range
600.0 V
0.1 V
1000 V
1 V
1000 V
< 3 kΩ
45 Hz ~ 400 Hz (sine)
)
AC/DC
Resolution
range
60.00 A
0.01 A
600.0 A
0.1 A
1500 A
1 A
60.00 A
0.01 A
600.0 A
0.1 A
1500 A
1 A
1500 A
45 Hz ~ 65 Hz (> 1000 A)
± 1 % of the measured value
BENNING CM 10–1
, A
and
(flexible AC current transformer)
AC
± (1.0 % + 7 digits), 45 Hz - 400 Hz, sine
AC/DC
AC/DC
AC/DC
Measurement accuracy
± (0.7 % + 7 digits)
± (0.7 % + 4 digits)
Measurement accuracy
± (2.0 % + 7 digits)
Measurement accuracy
± 2.0 % + 7 digits
± 2.0 % + 7 digits
29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

044688

Table des Matières