Manual storage (SAVE)

Set the data logger to manual storage "SAVE" by pressing a key according to
section 5.2.1. To enable the data logger, press the Bluetooth
LOG
conds until the „
key 5 is pressed, the current measured value is stored in the internal memory
and the corresponding storage location number is briefly shown on the digital
display K . Manual storage is stopped by pressing the Bluetooth
2 seconds.
Note:
The first start of the manual storage "SAVE" deletes the internal memory and
thus all stored measured values of the data logger "LOG". The manual storage
„SAVE" can then be started and stopped several times. The measured values are
continuously stored in the internal memory at the storage locations 0001 to 4000.

5.3 Data transmission to the smartphone/ tablet

The BENNING CM 10-1 is provided with a Bluetooth
real-time wireless transmission of measured values to an Android or IOS device.
The "BENNING MM-CM Link" app required for this is available in the Google Play
Store and in the Apple App Store.
Google Playstore
The "BENNING MM-CM Link" app offers i.a. the following functions:
-
Displaying of the measured values in real time and storage as CSV file.
-
Download of the data logger LOG (up to 4,000 measured values) from the
BENNING CM 10-1.
To activate the Bluetooth
BENNING CM 10-1 (symbol " " flashes). As soon as a Bluetooth
is established, the symbol " " is displayed permanently.
Range in open space: approx. 10 m
6.

Ambient conditions

-
The BENNING CM 10-1 is intended for making measurements in dry envi-
ronment.
-
Maximum barometric elevation for making measurements: 2000 m,
-
Overvoltage category / installation category of the BENNING CM 10-1:
IEC 60664/ IEC 61010 → 600 V category IV; 1000 V category III
-
Contamination class: 2,
-
Protection class: IP 30 (DIN VDE 0470-1, IEC/ EN 60529)
IP 30 means: Protection against access to dangerous parts and protection
against solid impurities of a diameter > 2.5 mm, (3 - first index). No protection
against water, (0 - second index).
-
Operating temperature and relative humidity:
For operating temperatures from 0 °C to 30 °C: relative air humidity lower
than 80 %,
For operating temperatures from 31 °C to 40 °C: relative air humidity lower
than 75 %,
For operating temperatures from 41 °C to 50 °C: relative air humidity lower
than 45 %.
-
Storage temperature: The BENNING CM 10-1 can be stored at temperatures
between - 10 °C and + 60 °C, at a relative air humidity lower than 80 % with-
out batteries.
11/ 2019
" symbol on the digital display K flashes. Each time the HOLD
LOG
2 Sec
interface, press the Bluetooth
®
BENNING CM 10–1
Press
LOG
>2Sec
2 Sec
Low Energy 4.0 interface for
®
key 7 for 2 se-
®
key 7 for
®
HOLD
App Store
key 7 at the
®
connection
®
28

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

044688

Table des Matières