2. Safety instructions
The instrument is built and tested in accordance with
DIN VDE 0411 Part 1/ EN 61010-1
DIN VDE 0411 Part 2-032/EN 61010-2-032
DIN VDE 0411 Part 2-033/EN 61010-2-033
DIN VDE 0411 Part 031/EN 61010-031
DIN VDE 0413 Part 13/EN 61557-13
and has left the factory in perfectly safe technical condition.
To preserve this condition and to ensure safe operation of the device, the user must observe
the notes and warnings given in these instructions at all times. Improper handling and non-
observance of the warnings might involve severe injuries or danger to life.
WARNING! Be extremely careful when working with bare conductors or main
line carrier! Contact with live conductors will cause an electric shock!
The BENNING CM 9-1 must be used in electrical circuits of overvoltage
category III with a conductor for a maximum of 600 V to earth or of overvoltage
category IV with a conductor for a maximum of 300 V to earth only.
Only use suitable measuring leads for this. With measurements within
measurement category III or measurement category IV, the projecting
conductive part of a contact tip of the measuring leads must not be longer
than 4 mm.
Prior to carrying out measurements within measurement category III and
measurement category IV, the push-on caps provided with the set and marked
with CAT III and CAT IV must be pushed onto the contact tips. The purpose of
this measure is user protection.
Please observe that work on live parts and electrical components of all kinds
is dangerous! Even low voltages of 30 V AC and 60 V DC may be dangerous
to human life!
Before starting the current clamp multimeter, always check the device as well
as all measuring leads for damages.
If it can be assumed that safe operation is no longer possible, switch the device off immediately
and secure it against unintended operation.
Safe operation can be assumed to be no longer possible, if
-
the device or the measuring leads exhibit visible damages,
-
the device no longer works,
-
the device has been stored under unfavourable conditions for a longer period of time,
-
the device was exposed to extraordinary stress during transport, or
-
if the device or the measuring leads are exposed to moisture.
Maintenance:
Do not open the multimeter, because it contains no components which can
be repaired by the user. Repair and service must be carried out by qualified
personnel only!
Cleaning:
Regularly wipe the housing by means of a dry cloth and cleaning agent. Do not
use any polishing agents or solvents!
3. Scope of delivery
The scope of delivery of the BENNING CM 9-1 comprises:
3.1 One BENNING CM 9-1
3.2 One safety measuring lead, red (L = 1.4 m)
3.3 One safety measuring lead, black (L = 1.4 m)
3.4 One compact protective pouch
3.5 Two 1.5 V micro batteries (IEC LR03/ AAA)
3.6 One operating manual
Parts subject to wear:
-
The BENNING CM 9-1 is supplied by means of two integrated 1.5 V micro batteries (IEC LR
03/ AAA).
-
The above mentioned safety measuring leads (tested spare part, part no. 044145) are
10/ 2020
BENNING CM 9-1
20