A07 • Lumbal pain
Specific program for the treatment of pain in the lumbar area. The intensity should be adjusted
to a level between the thresholds of perception and pain: the maximum intensity level is the
moment in which the muscles surrounding the area treated begin to contract; over this limit
stimulation does not become more effective, just more irritating, so it is best to stop before that
point. The first benefits can be seen after 15 to 20 treatments carried out on a daily basis;
proceed with the treatment until the symptoms pass. Program duration: 40 minutes.
Position of electrodes: see photo 27 in the manual of positions.
A07 Lombal pain
Electrodes Positioning: lumbar area (photo 27).
Phase 1
Tens microimpulses 30 min.
A08 • Sciatalgy
(Medical program)
Specific program for the treatment of pain in the sciatic area. The intensity should be adjusted
to a level between the thresholds of perception and pain: the maximum intensity level is the
moment in which the muscles surrounding the area treated begin to contract; over this limit
stimulation does not become more effective, just more irritating, so it is best to stop before that
point. The first benefits can be seen after 15 to 20 treatments carried out on a daily basis;
proceed with the treatment until the symptoms pass. Program duration: 30 minutes.
Position of electrodes: see photo 28 in the manual of positions.
A09 • Distortion/Contusion (Sprains / Bruises)
T-ONE EVO II)
The program develops its effectiveness after this type of injury by inhibiting pain locally,
producing three selectively acting, differentiated impulses. The intensity should be adjusted to
a level between the thresholds of perception and pain:
Number of treatments: until pain is lessened, on a daily basis (even 2/3 times a day).
A8 Sprains/Bruises
Electrodes Positioning: ankle (photo 32).
Phase 1
Tens rapid 15 min.
A10 • Inflammatory
Program recommended for inflammatory conditions. To be applied until the inflammatory state
is lessened (10-15 applications, once a day; the daily treatments can be doubled if required).
Identify the area to be treated and position the electrodes as shown in illustration 1. Adjust the
intensity until a tingling feeling is produced in the area treated; avoid contracting the
surrounding muscles.
Program duration: 30 minutes.
A11 • Vascularization
Has a vascularizing effect on the area treated. Vascularization increases arterial flow and
consequently aids the removal of algogenic substances and helps to restore normal
physiological conditions. Do not position the electrodes close to inflamed areas.
Daily application is recommended, the number of applications is not defined; the program can
be used to reduce pain.
Stimulation intensity should be between the thresholds of perception and slight discomfort.
IACER SRL
(Medical program)
(only on T-ONE EVO II)
(Medical program)
(Medical program)
(only on T-ONE EVO II)
Phase 2
Tens Burst 5 min.
(Medical program)
Phase 2
Haematomas impulse 15 min.
(only on T-ONE EVO II)
(only on T-ONE EVO II)
Total duration: 35 minutes
(only on
Total duration: 30 minutes
MNPG05-08 Ed. 12/10/10 Pag. 49

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

T-one evo ii

Table des Matières