Beretta BOILER B.A.I Série Manuel D'installation Et D'utilisation page 64

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 16
TABELUL 2
Putere termica focolara nominala incalzire/ACM (Hi)
Putere termica utila nominala incalzire/ACM
Putere termica focolara redusa incalzire (Hi)
Putere termica utila redusa incalzire
Putere termica focolara redusa producere ACM (Hi)
Putere termica utila redusa producere ACM
Eficienta de lucru Pn max - Pn min
Eficienta de lucru 30%
Randamentul combustiei
Putere electrica
Categorie
Tara
Voltaj alimentare
Nivel protectie
Pierderi cos si manta, arzator oprit
Functionare in regim incalzire
Presiune maxima - temperatura
Presiune minima pentru operare standard
Plaja selectare temperatura apa incalzire
Pompa: cap coloana maxim pentru capacitatea
sistemului
Membrana rezervor de expansiune
Preincarcare vas de expansiune (incalzire)
Functionare in regim ACM
Maximum pressure
Minimum pressure
∆t 25° C
Debit ACM
∆t 30° C
∆t 35° C
Plaja selectare temperatura ACM
Regulator de debit
Boilerului
Presiune gaz
Presiune gaz natural (G20)
Presiune GPL (G30/G31)
Conexiuni hidraulice
Incalzire tur - retur
ACM intrare - iesire
Intrare gaz
Dimensiuni si greutate centrala
Inaltime
Lungime
Latime
Greutate
Performanta ventilator
Presiune hidrostatica cu conducte concentrice de 0.85 m
Presiune hidrostatica centrala fara conducte
Rate de debit (G20)
Capacitate aer
Capacitate gaze arse
Curgere masa fluidizata (max-min)
Conducte de eliminare a fumurilor
Diametru
Conducte concentrice evacuare gaze si absorbtie aer
Diametru
Lungime maxima
Pierderi pentru un cot de 90°/45°
Gaura in perete (diametru)
Conducte duble evacuare gaze si absorbtie aer
Diametru
Lungime maxima
Pierderi pentru un cot de 90°/45°
Instalatie fortat-descisa (B22)
Diametru
Lungimea a tuburilor
Pierderi pentru un cot de 90°/45°
NOx
Valori emisii la minim si maxim gaz G20*
Maxim
CO s.a. mai mic decat
CO
2
Nox s.a. mai mic decat
∆t gaze
Minim
CO s.a. mai mic decat
CO
2
Nox s.a. mai mic decat
∆t gaze
* Boiler B.A.I.: testate cu Ø 130 (24 B.A.I.), Ø 140 (28 B.A.I.) - lung. 0,5m - temp. apa 80-60°C.
* Boiler B.S.I.: testate cu tevi Ø 80 (0.5 aer + 0.5 fum) separate - 90° sarcina - temp. apa 80-60°C - difragma de fum Ø 42 (24 B.S.I.), Ø 44 (28 B.S.I.).
B.A.I.
24kW
kW
26,70
kcal/h
22.962
kW
24,10
kcal/h
20.726
kW
10,40
kcal/h
8.944
kW
8,70
kcal/h
7.482
kW
10,40
kcal/h
8.944
kW
8,70
kcal/h
7.482
%
88,1 - 83,7
88,4 - 82,3
%
86,1
%
91,4
W
85
II2H3B/P
RO
V - Hz
230-50
IP
X4D
%
0,07-0,80
bar-°C
3 - 90
bar
0,45
°C
40 - 80
mbar
300
l/h
1000
l
10
bar
1
bar
8
bar
0,2
l/min
13,8
l/min
11,5
l/min
9,9
°C
40 - 63
l/min
10
l
60
mbar
20
mbar
30
Ø
3/4"
Ø
1/2"
Ø
3/4"
mm
940
mm
600
mm
465
kg
56,5
mbar
-
mbar
-
3
Nm
/h
50,041
3
Nm
/h
52,719
gr/s
18,04 - 16,78
19,91 - 17,98
mm
130
mm
-
m
-
m
-
mm
-
mm
-
m
-
m
-
mm
-
m
-
m
-
clasa 2
p.p.m.
80
%
6,00
p.p.m.
150
°C
121
p.p.m.
80
%
2,50
p.p.m.
130
°C
82
64
24kW
28kW
31,90
26,30
27.434
22.618
28,80
24,00
24.768
20.640
10,70
12,70
9.202
10.922
8,80
10,50
7.568
9.030
10,70
9,80
9.202
8.428
8,80
8,10
7.568
6.966
91,6 - 83,0
86,9
86,2
91,6
91,8
85
125
II2H3B/P
II2H3B/P
RO
RO
230-50
230-50
X4D
X4D
0,07-0,80
0,07-0,80
3 - 90
3 - 90
0,45
0,45
40 - 80
40 - 80
300
300
1000
1000
10
10
1
1
8
8
0,2
0,2
16,5
13,8
13,8
11,5
11,8
9,8
40 - 63
40 - 63
12
10
60
60
20
20
30
30
3/4"
3/4"
1/2"
1/2"
3/4"
3/4"
940
940
600
600
465
465
58,5
65
-
0,2
-
0,35
55,188
42,862
58,387
45,499
15,48 - 17,71
140
-
-
60-100
-
4,25
-
0,85/0,5
-
105
-
80
-
20 + 20
-
0,85/0,5
-
80
-
25
-
0,85/0,5
clasa 2
clasa 2
100
110
6,50
6,90
190
130
126
129
80
130
2,40
2,55
130
100
81
99
B.S.I.
28kW
31,00
26.660
28,00
24.080
12,70
10.922
10,50
9.030
10,50
9.030
8,70
7.482
92,1 - 83,2
87,9
92,4
125
II2H3B/P
RO
230-50
X4D
0,07-0,80
3 - 90
0,45
40 - 80
300
1000
10
1
8
0,2
16,1
13,4
11,5
40 - 63
12
60
20
30
3/4"
1/2"
3/4"
940
600
465
68
0,2
0,35
50,981
53,999
18,37 - 20,42
-
60-100
3,40
0,85/0,5
105
80
14,5 + 14,5
0,85/0,5
80
18
0,85/0,5
clasa 2
120
6,85
160
120
130
2,35
120
96

Publicité

Table des Matières
loading

Table des Matières