Factory wiring
The gearmotor is already connected.
To install the barrier on the right, follow the instructions in the PREPARING THE BARRIER paragraph.
Opening micro
switch
Closing micro switch
Warning devices
Barrier indicator light (contact rated for: 24 V AC - 3 W max).
It warns of the boom's raised position, and switches off when the boom is lowered.
Dome flashing light and/or luminous cord (Contact
rated for: 24 V - 32 W max.)
It flashes during the boom's opening and closing
phases.
Command and control
devices
STOP button (NC contact). It is for stopping the barrier while excluding automatic closing.
To resume movement, press the control button or one on another control device.
If unused, set DIP switch 9 to ON.
ONLY OPEN function from control device (NO contact).
Warning: in MAINTAINED ACTION mode, the control device must be connected to 2-3
ONLY OPEN or OPEN-CLOSED-INVERT (step-step)
function from control device (NO contact, see DIP
switch 2).
Set the jumper as shown in the fi gure.
ONLY CLOSE function from control device (NO contact).
Warning: in MAINTAINED ACTION mode, the control
device must be connected to 2-4.
Set the jumper as shown in the fi gure.
Orange
COM
White
NC
Orange
COM
Red
NC
}
}
24 V DC gearmotor
Blue
Brown