CAME G4040Z Manuel D'installation page 36

Masquer les pouces Voir aussi pour G4040Z:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

ELECTRICAL CONNECTIONS AND PROGRAMMING
⚠ Warning! Before working on the control panel, cut off the main current supply and, if present, remove any batteries.
Power supply to the control panel and control devices: 24 V AC/DC.
The features are set using the DIP switches, the adjustments using the trimmer.
All connections are quick-fuse protected.
FUSE TABLE
- Line
- Card
- Gearmotor
- Accessories
Description of parts
1. Accessories fuse
2. Line fuse
3. Control board fuse
4. Motor fuse
5. Terminals for control and safety devices
6. AF card connector
7. SENS trimmer
8. ACT Trimmer
9. DIP-SWITCH
5
Power supply
230 V AC, 50/60 Hz
Eyelet terminal with
screw and washer
for grounding
connection.
ZL38
3.15 A-F
630 mA-F
10 A-F
2 A-F
3
1
6
14
7 10
10. Programming button
11. Programming warning LED
12. Speed and slow-down adjusting connectors
13. Battery charger (LB38) connectors
14. Command type selection jumper
15. Transformer
16. Power supply terminals
17. Gearmotor terminal
18. Limit switch terminals
4
12
13
9
Terminals for powering up accessories:
- a 24 V AC normally;
- a 24 V DC when the emergency batteries are operating;
Overall allowed power: 40 W
15
2
16
17
18
11
8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

G4040iz

Table des Matières