MZ electronic EVVA-M Instructions D'utilisation page 24

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

By briefly pressing the ON button it is possible to enter the sensor menu where it is possible to set the
operating parameters of the sensor shown on the display; a long pressure of 3 seconds allows to enter
the main menu of the instrument.
Sensor menu
Use
(ON) key to access the instrument
setting menu. The following page will appear
on the display:
Use the
(DOWN) and
move around the menu options.
Once you are positioned on the item to be modified press the
choice.
Use the
(DOWN) or
Once one is positioned on the parameter press the
According to the type of parameter, using the
reduce/increase the value of the same or disable/enable the function.
VMAX
EVVA-M
Parameter
BackLight Time
Keyboard Beep
Language
Works Hours
VMAX (all sensors)
VMIN (all sensors)
IMAX (all sensors)
Name of the sensor
(UP) keys to
(UP) keys to move from one parameter to another.
Default value
30 seconds
Yes
Italian
0
16.0V
10.0V
10.0A
Sensor "x"
Sensor 1
V MAX
V MIN
I MAX
Sensor name
Exit
(ON) key to confirm your
(ON) key to enable modification.
(DOWN) and
(UP) keys it is possible to
Use the
(DOWN) and
to change the maximum voltage alarm
value from a minimum of 10.0V to a
maximum of 30.0V and confirm by
pressing (ON)
24
English
16.0
10.0
10.0
(UP) buttons
Rev. 01 – 2019

Publicité

Table des Matières
loading

Table des Matières