gb | 7. Mounting (specialist installer)
3. Place soffit element termination [14]
on soffit duct.
4. Fix soffit element termination to soffit
duct with the four self-tapping screws.
5. Place perforated plate grille [12] in the
soffit element termination.
6. Secure perforated plate grille with the
two screws provided.
7. Seal coupling between sleeve [17]
and wall insulation sleeve [11] with
silicone.
8. Have a specialist insulate space
between soffit duct and external wall.
9. Use the fastening lugs [15] and
polystyrene / insulation material
dowels
(5 mm in diameter, provided by
customer) to fix soffit duct to
insulation. Be sure to produce a
1...2 % inclination towards the
condensation drip edge [13].
 Condensation can drain out via the
drip edge.
10. Have a specialist insulate space
between soffit duct and external
plastering.
7.5 PP 60 KA-SR external cover
Undertake these steps if a
PP 60 KA-SR is being mounted.
1. Remove plaster protective cover on
outside if necessary.
 
34
2. Use hand saw or similar to saw off
upper half of wall insulation sleeve
flush with plaster.
 The bottom, longer half of the wall
insulation sleeve serves as a
condensation drip edge.
3. Seal drip edge of wall insulation
sleeve on outside with silicone.
4. Place frame of external cover [2] on
bottom half of wall insulation sleeve
[11].
5. Align frame of external cover [2] and
air deflector [3] horizontally and
centred in the middle to the wall
insulation sleeve.
6. Use dowels and screws (6 mm in
diameter, provided by customer) to
secure frame of external cover [2] and
air deflector [3] to external wall.
We recommend to install the air
i
deflector [3] between wall and
frame so that the outflowing air will