OPERATION
Settings and displays
4.4
Appliance settings
Key to symbols
Press once
Press once
Hold for 2 seconds
Change settings / scanning
Menu structure
OFF | 4 - 15 l/min
OFF | 20 - 60 °C
OFF | 1 | 2 | 3 | 4
OFF | 5 - 200 l
l/min
12:00
00:00 - 23:59
Auto
On
bernstein/amber
grün/green
Eur
cur
Eur
0_00...9999 €/kWh
cur
0_00...9999 cur/kWh
Eur
0_00...9999 €/m³
cur
0_00...9999 €/m³
CO2
0...2000 g/kWh
M
2 sec. /
time-out 30 sec.
26
|DHE SLi
START-menu
Change menu
END
OFF
1
OFF
2
OFF
3
OFF
4
l/min
5
6
Auto
7
100 %
8
100 %
9
0,22 €/kWh
10
0,22 cur/kWh
5,00 €/m³
11
5,00 cur/m³
553 g/kWh
12
13
14
15
1 ECO water and energy saving function
The ECO function enables you to limit the flow rate to a maxi-
mum value.
ECO on = symbol on user interface
ECO off = no symbol on user interface
2 Childproofing
Childproofing allows you as a user to limit the adjustable temper-
ature at the appliance to a maximum value. In service mode, the
contractor can also set a temperature for anti-scalding protection
(see chapter "Service mode"). This temperature then acts as the
upper limit of the setting range for childproofing.
3 Shower programs for good health
The shower program for good health lets you choose from 4 dif-
ferent shower programs.
WW = domestic hot water, KW = cold water
A Cold prevention
To strengthen the body, we recommend you finish off with a
cold shower; this will trigger a reflex in the body to warm up.
3 min
WW
KW
B Winter pick-me-up
An invigorating end to a winter shower with a final warm-up.
3 min
WW
10 sec
WW
- 10 °C
C Summer fitness program
The quick contrast shower to increase fitness with a final
warm-up.
3 min
WW
10 sec
KW
D Circulation program
Shower your arms and legs with cold water to boost circu-
lation. Spray from the hands and feet towards the body. You
can then repeat this process with warm water.
3 min
WW
20 sec
KW
4 Automatic water volume control
The automatic water volume control allows you to limit the volume
of water at a high flow rate. When the selected volume of water
is reached, the control automatically reduces the flow rate. The
preferred water temperature is maintained. The automatic water
volume control must be enabled on each occasion prior to filling
the bath. Example of filling a bath with 80 litres: When the bath
has been filled with 80 litres, the control automatically reduces
the flow rate to 4 l/min.
5 Flow rate
You have the option of displaying the flow rate or the time.
6 Setting the time
You have the option of displaying the time or the flow rate. You
can set a time from 00:00 h to 23:59 h. You will need to set the
time again following a power interruption.
10 sec
10 sec
10 sec
10 sec
10 sec
10 sec
30 sec
30 sec
20 sec
www.stiebel-eltron.com