Recommended Combinations - GYS TIG 250 AC/DC Mode D'emploi

Masquer les pouces Voir aussi pour TIG 250 AC/DC:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
t
Main button
T1
t
4T MODE
Main button
T1
Main button
T1
T2
Main button
T1
T2
4T MODE log
Main button
T1
T2
or
Main button
Secondary button
T1
T2
or
Secondary button
For this mode it may be convenient to use the dual button torch option or dual button with potentiometer. The «up» command keeps the same func-
tion as the single button or trigger torch. The «down» button can, when pressed, switch to the cold current. The potentiometer of the torch, where
available, can control of the welding current from 50% to 100% of the value displayed.
Summary of the fuctions available by welding process, by arcing mode and by type of trigger
Start
TIG
welding
HF
process
AC/DC STD
AC/DC
Pulse
AC/DC
Spot
(*) only on 4T LOG
(**) only on AC

RECOMMENDED COMBINATIONS

TIG : choix des consommables et des réglages en fonction de l'épaisseur
TIG DC
0,5-5
4-6
6-9
1-2,4
2,4-3,2
TIG AC
3,2-5,0
5-6,5
28
t
t
T2
T2
t
t
t
t
T3
T3
<0.5s
<0.5s
<0.5s
<0.5s
t
t
Trigger
Lift
2T
4T
4T
log
Current (A)
10-130
130-160
160-250
50-90
80-150
120-200
200-250
TIG 250 AC/DC
T1 - The main button is pressed, the cycle starts at PreGas and stops in
the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope and in
welding.
T3 - The main button is pressed, the cycle switches to DownSlope and
stops in I_Stop.
T4 - The main button is released, the cycle ends with PostGas.
Nb : for torches, double button and double button with potentiometer
=> command « up/welding current » and active potentiometer,
command «low » inactive.
T4
T4
>0.5s
T1 - The main button is pressed, the cycle starts at PreGas and stops in
>0.5s
the I_Start phase.
T2 - The main button is released, the cycle continues in UpSlope and in
welding.
t
LOG : this mode is used during welding :
- A brief press of the main button (<0.5s), the current switches from I
t
welding current to I cold and vice versa.
- the secondary button is kept pressed, the welding current switches
T4
T3
from I welding current to I cold
- the secondary button is kept released, the welding current switched
T4
T3
from I cold to I welding current.
T3 – A long press on the main button (>0.5s), the cycle swicthes to
DownSlope and stops in the I_Stop phase.
T4 - The main button is released, the cycle finishes with PostGas.
(*)
Ø Electrode (mm)
1,6
2,4
3,2
1,6
2,4
2-2,4
3,2
TIG Process
Flow rate
Ø Nozzle (mm)
(Argon L/min)
9,5
11
11-12.5
9,5
9,5
9.5-12.5
12.5-19.5
EN
(**)
(**)
(**)
(**)
(**)
(**)
6-7
7-8
8-9
6-7
7-8
8-10
10-12