LOCATION AND INSTALLATION
A 13" [33 cm) Depth of unprotected overhead cabinets.
B
30" [76.2 cm] MIN. (KGC30)
36" [91.4 cm] MIN. (KGC36)
C 18" [47.7 cm] MIN. Height from countertop to nearest cabinet on either side of unit.
D 30" [76.2 cm ] MIN. (see Note*) Clearance from countertop to unprotected overhead surface.
E
5" [12.7 cm] MIN. Clearance from cut out to side wall on the left and right of the unit.
F
From the back corner of cut-out to hole center 2-9/32" [5.8 cm].
G From the right corner of cut-out to hole center 2-19/32" [6.6 cm].
H From the back corner of cut-out to hole center 1-1/4" [3.2 cm]. Opening with oven under
cooktop.
I
From the top of countertop to hole center 6" [15.2 cm]. Opening with oven under cooktop.
L
Electric outlet from bottom of countertop and adjacent to the cabinet side 12" [30.5 cm].
– Hole 1-3/16" [3 cm].
* NOTE
If cabinet has a drawer, a 5-1/4"[3.2 cm] depth clearance from the top of the countertop to the
top of the drawer (or other obstruction) in base cabinet is required. The drawer depth may
need to be shortened to avoid interfering with the regulator.
24" [61 cm] min. clearance if bottom of wood or metal cabinets is protected by not less than
1/4" [0.6 cm] flame retardant millboard covered with not less than No. 28 MSG sheet steel
0.015" [0.04 cm] stainless steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper.
30" [76.2 cm] min. clearance between top of cooking platform and bottom of unprotected
wood or metal cabinet.
(continued)
Figure 9.
Cutout Requirements (2/2)
©2019 Hestan Commercial Corporation
EN
7