CONVERSION
REPLACING ORIFICES ON STACKED BURNER (KGC36)
1) Remove the grates and burner caps (A).
EN
2) Remove gas spreader (B).
3) Loosen orifices (C) by turning 9/32" nut driver
counter-clockwise.
4) Install the orifices supplied with this appliance in
the appropriate burner. Each orifice has a number
stamped on the side, which identifies the orifice
diameter. (See Figure 23 for the orifices to use in
each burner position).
5) Turn clockwise to tighten. Tighten to a torque of
15 to 20 inch-lbs. [1.7-2.3 N-m].
6) Replace all parts following the reverse order.
7) Save the orifices removed from the appliance for
future use.
1.5
1.3
0.54
1.75
0.54
1.75
Figure 23. Orifice Locations
20
©2019 Hestan Commercial Corporation
(continued)
N
G
MAIN FLAME SIMMER
0.75
1.45
1.45
MAIN FLAME SIMMER
1.45
1.45
0.75
C
Figure 22. Stacked Burner
KGC 30 Orifices
1.5
.094
1.3
0.72
KGC 36 Orifices
0.37
0.54
1.10
1.75
0.37
0.54
1.10
1.75
A
B
L
P
c
o
n
e v
s r
o i
n
MAIN FLAME SIMMER
0.85
0.85
0.5
MAIN FLAME SIMMER
0.5
0.85
0.85
0.94
0.72
0.37
1.10
0.37
1.10