MagnaTherm FT User's Manual

4. In the Event of Power Failure

The MagnaTherm will not operate during an electrical power outage. If there is an extended power outage
with danger of freezing, then the MagnaTherm (and all other water systems) should be completely drained.
Before draining the unit, turn off the gas and turn off the main power switch. When you replace the unit in
service, refer to the "Installation and Operation Manual" for instructions on filling and purging.

5. General Care

Keep the area around the MagnaTherm clear and free from combustible materials, gasoline and other
flammable vapors and liquids. Clean the jacket surfaces with a damp cloth and mild soap. Do not use
flammable cleaning materials. Keep the vent terminal free of obstructions. Do not pile snow against the vent
terminal.

6. Annual Inspection and Service

You should visually inspect the vent pipe once a year. Should any corrosion or leaks exist, have the affected
parts replaced.
Once each year a qualified service agency should conduct a detailed inspection of all flue product carrying
areas of the boiler and vent system. Follow the service instructions in the "Installation and Operating
Instructions Manual" for the MagnaTherm.
Once each year inspect the condensate drain line, vent line, condensate PVC fittings, the condensate
trap and condensate neutralizer (if installed). If necessary, disassemble and flush with fresh water and
reassemble.
Once each year inspect and clean the air inlet filter. See the Section 11 of your units Installation and
Operation Instructions for a complete list of maintenance items.

7. For Service

Contact your installing contractor, gas utility, Laars dealer, or check www.Laars.com for the nearest
authorized representative in your area.
8. About Lockouts, Limits and Alarms
The system responds to three kinds of trouble indications:
is caused by a serious problem that might involve a safety issue. Once the controller enters
Lockout
A
a lockout, the burners will shut down, and will not be allowed to run again until the cause of the problem
is corrected, and you reset the control system. If the lock-out does not reset, or the lock-out condition
continues to occur, contact a qualified service agency to restore the unit to normal operations.
See the Installation and Operation Instructions for the full list of lockouts.
which will cause the boiler to shut down but allow restart when the fault goes away
Limits
There are also
or the limit value is no longer exceeded. In this case, operator intervention is not required. An example of
this is a water flow switch safety limit. If the water flow to the boiler drops below a pre-set value, the unit
will shut down but restart when the correct flow rate is re-established. In some cases, if the fault continues
to occur, the system will enter a Lockout condition.
conditions are indicated through lockout banners and/or messages. Lockout conditions are
Alarm
annunciated with a red banner at the top of the display and a corresponding code. The message icon will
show an exclamation point when there is a message. Messages will provide information regarding the
status of the unit and the condition limiting operation.