Burkert 2000 Instructions De Montage page 28

Masquer les pouces Voir aussi pour 2000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.3.2.
Installation and commissioning
② instead of transparent cap onto actuator
Screw adapter
(see "Fig. 16: Actuators K-175, L-225 with electrical position
repeater").
Screw electrical position repeater
(see "Fig. 16: Actuators K-175, L-225 with electrical position
repeater").
electrical connection
(see "Fig. 17: Connection of the appliance socket")
Fig. 17: Connection of the appliance socket
③ on the appliance socket and remove.
Loosen cap screw
28
All manuals and user guides at all-guides.com
① into adapter ②
Pos. designation of parts
1
Flange sealing
2
Contact insert
3
Cap screw
4
Cap
5
Pressure ring
6
Flat seal
7
Collet
8
Coupling nut
english
Type 2 000, 2002, 2012
Option: Electrical position repeater
note!
functional failure due to buckled connector lugs preventing
re-installation of the contact insert!
Carefully remove the contact insert and take care to ensure that
the connector lugs do not become buckled.
④ and remove contact insert ②.
Loosen screw in the cap
Lead cable through coupling nut
Make connection as per circuit diagram
(see „Fig. 18: Electrical WAFitsching").
Max. rating:
5 A at 250 V AC
0,25 A at 250 V DC.
Fig. 18:
Electrical WAFitsching
② in the cap ④ and screw on.
Place contact insert
Screw on appliance socket with cap screw
seating of the flat seal ⑥.
Test valve for function and leaktightness.
2030, 2031; 2032, 2033
⑧.
Assignment: 1.
Input
2. Break contact
3. Make contact
③, assuring proper

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

200220122030203120322033

Table des Matières