Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

GB

ELIMINATING FAULTS

10
ELIMINATING FAULTS
MALFUNCTION
Mortar spraying machine not
running.
Green operating light lights up
Mortar spraying machine not
running.
Green operating light not does
not light up
Mortar spraying machine not
running.
Red indicator light lights up
Mortar spraying machine can-
not be switched on/off by
means of the remote control.
Mortar spraying machine can-
not rotate the rotor
Mortar spraying machine builds
up pressure in the mortar hose.
However, coating material does
not arrive at the spray lance.
44
POSSIBLE CAUSE
Delivery volume controller is set to „ 0"
Lance control cable not connected or
damaged
Power supply missing.
Mortar spraying machine was over-
loaded/overheated.
Remote control line not connected or
defect.
Rotor stuck in stator.
Pump was not lubricated with pump
sliding means.
Coating material "plug" in the mortar
hose. Mortar hose not prerinsed with
cellulose paste.
PowrPlast 1000
ELIMINATION
Increase delivery volume
Check control cable
- Plug in the power plug.
- Check the power cable for damage and replace,
if necessary.
- Check the power supply.
Close material tap and disconnect mains plug.
Switch the mortar spraying machine on again after
about 5 minutes.
Connect remote control, check connections, check
remote control line for damage.
Set the selector switch alternatively briefly to "F"
(forwards) – "R" (reverse).
Contact Titan customer service if the problem can-
not be resolved.
Depressurize the mortar hose – set the selector
switch to "R" (reverse).
Pump the coating material back into the con-
tainer.
The mortar hose must be pres-
sureless.
Watch the manometer ––> 0 bar.
Wear safety goggles.
Decouple mortar hose and rinse with water hose.
When the plug has been removed, ll cellulose
paste in the mortar hose. Couple the mortar hose
back on.

Publicité

Table des Matières
loading

Table des Matières