9. Install the top section on top of or above the middle
section.
D O
N O
I N
T H
10. Apply wall fi nish over top of framing kit and secure
using sefl -tapping screws into framing kit and
appliance case.
11. Complete installation of vent, HeatShift and
fi replace. See installation manuals.
8
T
S C
I S
R E
Z O
W
N E
!
To accommodate various ceiling heights,
either fasten upper section to ceiling and
have the wall finish span the gap between
the upper and middle sections OR add
framing/shims between the upper and middle
sections - added framing/shims can be wood
or steel.
Note: If using LDK7 Duct Termination
Plates the top section of framing kit
must be minimum 2-1/2" below
finished ceiling height.
Minimum non-combustible zone
required for wall finish and anything
within framing cavity. No combustible
framing or wiring allowed in cavity
within this area. Refer to LX2
installation manual for other
clearances.
/ 4 "
- 1
1 1
"
1 / 4
5 -
Bottom flange of opening
S e e a p p l i a n c e a n d
H e a t S h i f t i n s t a l l a t i o n
m a n u a l s f o r
r e q u i r e m e n t s a b o u t
c e m e n t b o a r d , w a l l
f i n i s h a n d c l e a r a n c e s t o
c o m b u s t i b l e m a t e r i a l s .