11. EMC TABLES
GUIDANCE AND MANUFACTURER'S DECLARATION – ELECTROMAGNETIC EMISSIONS
The Lumina Smart is intended for use in the electromagnetic environment specified below. The customer or the user
of the Lumina Smart should assure that it is used in such an environment.
Emissions test
RF emissions CISPR 11
RF emissions CISPR 11
Harmonic emissions
IEC61000-3-2
Voltage fluctuations/flicker
emissions IEC 61000-3-3
GUIDANCE AND MANUFACTURER'S DECLARATION – ELECTROMAGNETIC IMMUNITY
The Lumina Smart is intended for use in the electromagnetic environment specified below. The customer or the user
of the Lumina Smart should assure that it is used in such an environment.
Immunity test
Electrostatic discharge
(ESD) IEC 61000-4-2
Electrical fast
transients/bursts
IEC 61000-4-4
Surge
IEC 61000-4-5
Voltage dips
IEC 61000-4-11
Voltage interruptions
IEC 61000-4-11
Rated Power frequency
magnetic field IEC
61000-4-8
NOTE: U
: rated voltage(s); E.g. 25/30 cycles means 25 cycles at 50Hz or 30 cycles at 60Hz.
T
Compliance
Group 1
Class B
Class A
Complies
IEC 60601 test level
+/- 8 kV contact
+/- 2 kV, +/- 4 kV,
+/- 8 kV, +/- 15 kV
air
±2 kV
100 kHz repetition
frequency
Line to line:
±0,5 kV, ±1 kV
Line to earth:
±0,5 kV, ±1 kV, ± 2kV
0% U
; 0.5 cycle at 0°,
T
45°, 90°, 135°, 180°, 225°,
270°, and 315°
0% U
; 1 cycle and 70%
T
U
; 25/30 cycles
T
sine phase at 0°
0% U
; 250/300 cycle
T
30 A/m
50Hz or 60Hz
Electromagnetic environment - guidance
The Lumina Smart uses RF energy only for its
internal function. Therefore, its RF emissions
are very low and are not likely to cause any
interference in nearby electronic equipment.
The Lumina Smart is suitable for use in all
establishments, including domestic establishments
and those directly connected to the public
low-voltage power supply network that supplies
buildings used for domestic purposes.
Compliance level
+/- 8 kV contact
+/- 2 kV, +/- 4 kV,
+/- 8 kV, +/- 15 kV
air
±2 kV
100 kHz repetition
frequency
Line to line:
±0,5 kV, ±1 kV
Line to earth:
±0,5 kV, ±1 kV, ± 2kV
0% U
; 0.5 cycle at 0°,
T
45°, 90°, 135°, 180°,
225°, 270°, and 315
0% U
; 1 cycle and 70%
T
U
; 25/30 cycles
T
sine phase at 0°
0% U
; 250/300 cycle
T
30 A/m
50Hz or 60Hz
Electromagnetic environment
- guidance
Floors should be wood, concrete
or ceramic tile. If floors are
covered with synthetic material,
the relative humidity should be
at least 30 %.
Mains power quality should be
that of a typical commercial or
hospital environment.
Mains power quality should be
that of a typical commercial or
hospital environment.
Mains power quality should be
that of a typical commercial or
hospital environment. If the user
of devices require continued
operation during power mains
interruptions, it is recommended
that devices be powered form an
uninterruptible power supply or
a battery.
Power frequency magnetic field
should be at levels characteristic
of a typical location in a typical
commercial or hospital environ-
ment.
35