Transport; Maintenance; Storage; Electrical Connection - PrimAster KZS-UG2000 Traduction Des Instructions D'origine

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

• Repeat the previous points on all four legs. (fig.
25/26)
• Place the transverse strut (C) over the longitudinal
strut (E) and insert the guide lugs into the leg (A).
Fasten the struts with the screws, washers and
nuts (a) in the holes provided. (fig. 27)
• Repeat the process on the opposite side.
• Insert the longitudinal strut (D) with the guide nose
into the notch provided on the leg (A) and screw
it together with the screws, washers and nuts (a)
supplied. (fig. 28)
• Screw the top transverse strut (B) to the hole pro-
vided on the leg (A) using the screws, washers and
nuts (a) supplied. (fig. 28)
• Place the mitre saw on the machine stand and move
it until the holes of the saw are aligned with those in
the machine stand. Then tighten the mitre saw with
the screws, washers and nuts (b) supplied.

9. Transport

• Tighten the handle (11) to lock the rotary table.
• Press the machine head (4) downwards and secure
with the locking bolt (23).
• Fix the saw's drag function with the locking screw
for drag guide (20) in rear position.
• Carry the equipment by the fixed saw table (15).
• When reassembling the equipment proceed as de-
scribed under section 7.

10. Maintenance

m Warning! Prior to any adjustment, maintenance or
service work disconnect the mains power plug!
General maintenance measures
Wipe chips and dust off the machine from time to time
using a cloth. In order to extend the service life of the
tool, oil the rotary parts once monthly. Do not oil the
motor.
When cleaning the plastic do not use corrosive prod-
ucts.
Cleaning the moving saw blade guard safety de-
vice (5)
Always check the saw blade guard for debris before
using the machine.
Remove old sawdust and splinters using a brush or
similar tool.
Replacing the table insert
Danger!
• With a damaged table insert (10) there is a risk of
small parts getting stuck between table insert and
saw blade, blocking the saw blade. Immediately
replace damaged table inserts!
34 | GB
1. Remove screws at table insert. If required, turn
rotary table and incline saw head to be able to
reach the screws.
2. Remove table insert.
3. Install new table insert.
4. Tighten the screws at table insert.
Brush inspection
Check the carbon brushes after the first 50 operat-
ing hours with a new machine, or when new brushes
have been fitted. After carrying out the first check,
repeat the check every 10 operating hours.
If the carbon is worn to a length of 6 mm, or if the spring
or contact wire are burned or damaged, it is necessary
to replace both brushes. If the brushes are found to be
usable following removal, it is possible to reinstall them.
When servicing the carbon brushes, open the two
latches counterclockwise (as shown in Figure 21).
Then remove the carbon brushes.
Replace the carbon brushes in the reverse order.
Service information
Please note that the following parts of this product
are subject to normal or natural wear and that the fol-
lowing parts are therefore also required for use as
consumables.
Wear parts*: carbon brushes, saw blade, table in-
serts, sawdust bags
* Not necessarily included in the scope of delivery!

11. Storage

Store the device and its accessories in a dark, dry and
frost-proof place that is inaccessible to children. The
optimum storage temperature is between 5 and 30˚C.
Store the electrical tool in its original packaging.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.

12. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies
with the applicable VDE and DIN provisions.
The customer's mains connection as well as
the extension cable used must also comply with
these regulations.
Important information
In the event of an overloading the motor will switch
itself off. After a cool-down period (time varies) the
motor can be switched back on again.
With a single-phase a.c. motor, we recommend a C
16A or K 16A fuse for machines with a high start-up
current (from 2000 Watt)!