Warning! This electric tool generates an electromag-
netic field during operation. This field can impair active
or passive medical implants under certain conditions.
In order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the electric tool.

6. Technical data

AC motor
Power S1
Idle speed n
0
Carbide saw blade
Number of teeth
Maximum tooth width of saw
blade
Swivel range
Mitre cut
Saw width at 90°
Saw width at 45°
Saw width at 2 x 45° (double
mitre cut)
Protection class
Weight:
Crosscut, drag and mitre saw
Machine stand
Laser class
Wavelength of laser
Laser output
Technical changes reserved!
The work piece must have a minimum height of 3
mm and a minimum width of 10 mm.
Make sure that the workpiece is always secured
with the clamping device.
Noise
Total noise values determined in accordance with EN
62841.
Sound pressure level L
pA
Uncertainty K
pA
Sound power level L
WA
Uncertainty K
pA
Wear hearing protection.
The effects of noise can cause a loss of hearing
30 | GB
220 - 240 V 50Hz
2000 Watt
4500 min
-1
ø 255 x ø 30 x 2,8
mm
48
2,8 mm
-45° / 0°/ +45°
0° bis 45° nach
links
340 x 90 mm
240 x 90 mm
240 x 45 mm
II
ca. 14,3 Kg
ca. 4,4 Kg
2
650 nm
< 1 mW
101,6 dB(A)
3 dB
114,6 dB(A)
3 dB
The above-mentioned noise emission values were
measured in accordance with a standardised test
procedure and can be used to compare one power
tool with another.
The above-mentioned noise emission values can
also be used for the preliminary assessment of ex-
posure.
Warning:
• The noise emissions during the actual use of the
power tool may differ from the above-mentioned
values depending on the power tool being used, in
particular on the type of workpiece being processed.
• Try to keep emissions as low as possible, for ex-
ample by limiting your working time. In this regard,
all the operational cycle phases must be taken into
consideration (such as the times when the tool is
switched off or running idle).

7. Before starting the equipment

• Open the packaging and remove the device care-
fully.
• Remove the packaging material as well as the
packaging and transport bracing (if available).
• Check that the delivery is complete.
• Check the device and accessory parts for trans-
port damage.
• If possible, store the packaging until the warranty
period has expired.
ATTENTION
The device and packaging materials are not toys!
Children must not be allowed to play with plas-
tic bags, film and small parts! There is a risk of
swallowing and suffocation!
• The equipment must be set up where it can stand
securely. Secure the machine on a workbench or a
base frame with 4 screws (not included in delivery)
using the holes on the fixed saw table (15).
• Pull out the pre-installed tilt protection (37) com-
pletely and secure it with an Allen key (D).
• All covers and safety devices have to be properly
fitted before the equipment is switched on.
• It must be possible for the blade to run freely.
• When working with wood that has been processed
before, watch out for foreign bodies such as nails
or screws, etc.
• Before you press the ON/OFF switch check that the
saw blade is fitted correctly. Moving parts must run
smoothly.
• Before you connect the equipment to the power
supply make sure the data on the rating plate are
dentical to the mains data.