FAILURE DETECTION ON HEATING
DEVICE
NORMAL OPERATION
The plug fitted in the panel is placed in the posi-
tion corresponding to "Resistance ON"
(see drawing on the right).
When the remote control closes, the LED lights up
and, after about two minutes, the burner starts up.
BURNER DOES NOT OPERATE
1) If the LED is OFF, the heating resistance
placed in the nozzle-holder is off.
2) If the LED is ON and nevertheless the burn-
er does not run, place the plug in the posi-
tion
corresponding
OFF"
(see drawing on the right).
If the motor runs, the delaying device inside
the control box is out of order.
3) If the motor does not run, it means that the
failure is neither in the panel nor in the re-
sistance, but elsewhere.
2666
to
"Resistance
9
CONTROL BOX 531SE
PLUG
Resistance ON
PLUG
Resistance OFF
GB
*
S7059
LED
S7060
LED