13. Display Indications

The LED Display (3) has three colored LEDs which are used to indicate the status of the
System.
LED Indications During Normal Use
T T u u r r n n o o n n
T T u u r r n n o o n n
LED Check
LED Check
System
System
Start Up
Start Up
Battery Level Indication
Battery Level Indication
Under 4 hours
4 to 8 hours
Under 4 hours
4 to 8 hours
1
1
System
System
Check
Check
S S y y s s t t e e m m F F a a u u l l t t
Standard
S S y y s s t t e e m m F F a a u u l l t t
Standard
Operating
Operating
Mode
Mode
S S y y s s t t e e m m O O F F F F
S S y y s s t t e e m m O O F F F F
G G l l o o s s s s a a r r y y
G G l l o o s s s s a a r r y y
System Fault: Operating Mode that verifies in case of "Empty
1
System Fault: Operating Mode that verifies in case of "Empty
Gas Canister" or "System Error" (see Section 18,
1
Off On
Blink
Gas Canister" or "System Error" (see Section 18,
"Troubleshooting")
Off On
Blink
System Active: Operating Mode that verifies in case the System
"Troubleshooting")
2
B B a a t t t t e e r r y y R R e e c c h h a a r r g g e e
System Active: Operating Mode that verifies in case the System
Duration
Check is successfully passed (see Section 12, "System
2
Duration
Check is successfully passed (see Section 12, "System
Operation")
Operation")
LED Indications During Recharge
B B a a t t t t e e r r y y R R e e c c h h a a r r g g e e
Under 8 hours
8 to 18 hours
18 to 30 hours
G G l l o o s s s s a a r r y y
Fully charged
18 EN
G G l l o o s s s s a a r r y y
3s
3s
1s
1s
3s
3s
Over 8 hours
Over 8 hours
1s
1s
2
2
In case of
In case of
Low Battery
System Check
Low Battery
System Check
Min 10s
Min 10s
Max 60s
Max 60s
In case of
In case of
S S y y s s t t e e m m A A c c t t i i v v e e
Low Battery
S S y y s s t t e e m m A A c c t t i i v v e e
Low Battery
S S y y s s t t e e m m O O N N
S S y y s s t t e e m m O O N N
Under 8 hours
8 to 18 hours
18 to 30 hours
Fully charged
Off On
Blink
IMPORTANT!
The solid green LED (3a) indicates that the System is on.
WARNING!
Any LED indication different from the solid green LED (3a) indicates
that the System is not active and accordingly will NOT deploy in a
crash.
Indications during battery charging
During battery charging the LED Display (3) will show a continuous flashing. When the
battery is fully charged all 3 LEDs will remain illuminated.
14. Cleaning, Storage and Transportation
Vest Cleaning
Use only a cloth dampened with water to clean the vest (fabric and plastic parts). Solvents or
chemical cleaners must not be used, as they may compromise the integrity of the System.
WARNING!
Under NO circumstances should the vest be washed in a washing
machine, submerged in water, tumble dried or ironed. This may cause
permanent damage to the System and cause malfunction.
Tip:
As part of the recommended two-yearly service the System will be
disassembled and washed.
Storage
When not in use it is recommended to store the System in its original packaging. It may
be stored flat provided that no heavy or sharp objects are placed on top of it. The System
can also be stored hung up from a rail. It should always be stored in a cool, dry place, out
of direct sunlight.
The battery of the System slowly self-discharges, even if the System is not turned on, in
particular if the System is stored in a warm environment. It is thus recommended that even
whilst in storage the System be periodically recharged (at least once every 18 months) to
prevent battery drainage and shortening the battery life.
IMPORTANT!
If the battery becomes fully drained, the System may require a longer
time to recharge. It is thus recommended that the System is periodically
recharged as indicated.
WARNING!
Do NOT leave the System in direct sunlight inside a closed car or
otherwise exposed to high temperatures. High temperatures will
damage the battery and possibly the other electronics of the unit.
WARNING!
Zipping up the vest and closing the Front Flap (2) will cause the
System to turn on. To prevent this, it is essential that the Front
Flap (2) is opened, in order to prevent accidental activations of the
System. Failure to do so will cause the System to turn on, which will
cause the battery to drain. When storing the System remember to
keep the Front Flap (2) open and check that there are no indicator
lights illuminated on the LED Display (3).
WARNING!
The System's storage temperature must be between -20°C and +60°C
(-4°F to 140°F). Exposure to a temperature lower than -20°C (-4°F)
may cause permanent damages to the battery.
Transportation
Users should be aware that airbag inflators are pyrotechnic devices. Under the European
pyrotechnic Directive (2007/23/EC) they are certified safe for transportation, including by
air, provided that the System is checked into the aircraft's hold as checked luggage.
When transporting the System by air, users are strongly recommended to download and
print a copy of the Product Information Sheet (PIS) in case they are questioned by airport
staff. This can be downloaded from the Tech-Air® App (Section 17).
Note: Not all countries worldwide permit the import of pyrotechnic devices. Prior to
traveling, users should check with the appropriate authorities of countries through which
and to which they are traveling to determine if the System will be permitted entry or not.
Product Information Sheet (PIS) can be downloaded using the Tech-Air® App.