Troubleshooting Chart - SPX Flow Johnson Pump WPS 2.9 Manuel D'instruction

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 19
> English
Trouble-shooting chart
Symptom
1. Pump does not run.
2. Pump does not prime.
3. Pump cycles on and off
rapidly while water is
demanded.
4. Pump cycles on and off
rapidly while water is not
demanded.
5. Pump will not stop running
when water is not demanded.
6. Low flow/pressure.
7. Pump is excessively noisy.
12
Cause
1.1 Tripped thermal protector or blown
fuse.
1.2 Faulty wire connection or power
source.
1.3 Pressure switch malfunctioning.
1.4 Motor malfunctioning.
1.5 Pump/motor frozen.
2.1 Water tank empty.
2.2 Debris under valves.
2.3 Perforated diaphragm.
2.4 Leak on inlet side of pump.
2.5 Inlet or outlet plumbing restricted.
3.1 Restriction on outlet side of pump/too
high pressure.
4.1 Leak on outlet side of pump.
5.1 Leak on inlet side of pump.
5.2 Leak on outlet side of pump.
5.3 Perforated diaphragm.
5.4 Water tank empty
5.5 Pressure switch malfunctioning.
5.6 Low voltage to pump.
6.1 Leak on inlet side of pump.
6.2 Leak on outlet side of pump.
6.3 Perforated diaphragm.
6.4 Motor malfunction.
6.5 Debris under valves.
7.1 Pump is plumbed directly to rigid
tubing.
7.2 Pump head loose on motor.
7.3 Pump mounting is loose.
7.4 Pump mounting is too rigid.
7.5 Defective motor.
Remedy
1.1.1 Check fuse. If motor is overheated let
it cool down prior to restart.
1.1.2 Check battery/power supply, main
switch and wiring.
1.1.3 Change pressure switch.
1.1.4 Change pump.
1.1.5 Thaw pump and system and check
for damage. The pump/motor is liable
to damage when a frozen pump is
started
2.1.1 Fill up tank.
2.1.2 Carefully flush pump with tap water at
nominal pump flow. Note! Flush in
nominal flow direction.
2.1.3 Replace diaphragm kit.
2.1.4 Check tightness of hose connections at
pump, filter and tank.
2.1.5 Check plumbing.
3.1.1 Outlet hose too small, must be of same
diameter as pump connection.
4.1.1 Check tightness of hose connections,
check hose for possible damage.
5.1.1 Check tightness of hose connections,
check hose for possible damage.
5.1.2 Check tightness of hose connections,
check hose for possible damage.
5.1.3 Replace diaphragm kit.
5.1.4 Fill up tank.
5.1.5 Change pressure switch.
5.1.6 Change battery/power supply.
6.1.1 Check tightness of hose connections,
check hose for possible damage.
6.1.2 Check tightness of hose connections,
check hose for possible damage.
6.1.3 Replace diaphragm kit.
6.1.4 Change pump.
6.1.5 Carefully flush pump with tap water
at nominal pump flow. Note! Flush in
nominal flow direction.
7.1.1 Install flexible tubing according to
installation recommendation, see
page 9.
7.1.2 T ighten screws.
7.1.3 T ighten screws.
7.1.4 Use flexible tubing and make sure
the dampening rubber feet are used.
7.1.5 Change pump.
Original instructions

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Johnson pump wps 3.5Johnson pump wps 4.0Johnson pump wps 5.2

Table des Matières