pressure in the normal range) the graphic classification on the
unit indicates the higher range (high-normal in the example
described).
Blood pressure value
category
Setting 3:
severe
red
hypertension
Setting 2:
moderate
orange 160 – 179
hypertension
Setting 1:
mild
yellow
hypertension
High normal
green
Normal
green
Optimal
green
Source: WHO, 1999 (World Health Organization)
7. Saving, retrieving and deleting results
• The results of each successful measurement are stored
together with date and time. With more than 30 items of
measured data, the earliest items of data measured are lost.
• Use the SET button and then the -/+ buttons to select the
desired user memory and confirm using the button
ing the M+ button displays the average value AVG of the 3
most recent measurements stored in the user memory. By
All manuals and user guides at all-guides.com
Systole
Diastole
Action
(in mmHg)
(in mmHg)
seek medical
≥ 180
≥ 110
attention
seek medical
100 – 109
attention
regular mo-
140 – 159
90 – 99
nitoring by
doctor
regular mo-
130 – 139
85 – 89
nitoring by
doctor
120 – 129
80 – 84
self-monitoring
< 120
< 80
self-monitoring
pressing the + button, the most recent measurements are
displayed; by pressing the - button, the oldest are displayed.
• The average value AVG can only be displayed if there are 3
saved values in the respective user memory.
• To clear the memory, you must first select a user memory.
Hold the SET button pressed for approx. 3 seconds. All the
values in the current user memory are deleted after 3 brief
beeps are output.
• If you wish to change the user memory, see "Select memory".
8. Cleaning and storing the device and cuff
• Clean the device and cuff carefully using a slightly damp
cloth only.
• Do not use any cleaning agents or solvents.
• Under no circumstances hold the device and cuff under wa-
ter, as this can cause liquid to enter and damage the device
and cuff.
• If you store the device and cuff, do not place heavy objects
on the device and cuff. Remove the batteries. The cuff line
should not be bent sharply.
9. Error messages / troubleshooting
In case of faults, the
Error messages can occur when
1. inflation pressure is higher than 300 mmHg,
2. blood pressure is unusually high or low,
3. you move or talk during the measurement.
In such cases, repeat the measurement. Ensure that the cuff
. Press-
line is correctly attached and that you do not move or speak
during the measurement. If necessary, reinsert or replace the
batteries.
21
message appears in the display.
Err