DISPLAY DATA
DESCRIPTION
Strt
Operation modes
no
- Start inputs from terminal board are disabled
StAn
- Standard operation
APCH
- Separated opening and closing commands
PrES
- Manned operation
oroL
- Timer operation
StoP
STOP input
no
- STOP input not available
invE
- STOP command stops the gate: START command starts
moving in the opposite direction
ProS
- STOP command stops the gate: pressing the START command
gate continues the motion
Foto
Photocell input
CFCh
- Photocell is active in closing and also when the gate is still
no
- Not available
Ch
- Photocell is active during the closing
tESt
Test of safety devices
no
- Function not active
Foto
- Test enabled only for photocells
CoSt
- Test only enabled for the safety edges (or for the additional photocells)
Ft.Co
- Test enabled either for photocells or for safety edges
ShAd
Photocell shadow zone
no
- Function disabled
F.ShA
- Time of end disabling
i.ShA
- Time of beginning enabling
CoSt
Border input
no
- Input disabled (the control unit ignores it)
Fot.i
- Input enabled for the additional photocells active during opening and closing
rESi
- Input enabled for conductive rubber ribbons
StAn
- Input enabled for standard safety ribbons with normally closed contact
AP.Ch
- Input enabled in opening and closing phase
AP
- Input enabled only in opening phase
Ch
- Input enabled only in closing phase
FC.En
End of stroke inputs
no
- Input disabled (the control unit ignores it)
rALL
- Inputs enabled: the gate starts the slowdown phase (menu t.rAL) near
the limit switches
StoP
- Input enabled: the gate stops near the limit switches
i.Adi
no/Si
Enabling the ADI device
t.inA
0 ÷ 8
Max. gate quiescent time
ASM
0.5"÷2.0'
Anti-skid
no
- Function disabled
SEnS
0 ÷ 10
Obstacle sensor level
Cont
Counter viewing
tot.
- Total number of completed cycles (views in thousands or in units)
Man
- Number of cycles before the next request for service (such a number has
been rounded off to hundreds and it can be set up on 1000-step; in
case it is set up on 0, the request will be disabled and no will be viewed)
APPr
Automatic learning of the operation time
no
- Function disabled
Go
- Start up of the automatic learning procedure
FinE
End of programming
no
- It does not exit from the program menu
Si
- It exits from the program menu by storing the setup parameters