Télécharger Imprimer la page

Quick Configuration - V2 SPA CITY4 Mode D'emploi

Centrale digitale universelle pour le controle d'un moteur a 230v/120v

Publicité

Les langues disponibles

Les langues disponibles

Function menu setup
Function menus allow selecting a function from among a group
of available options. When you enter into a function menu, the
current active option will be viewed; you can scroll all available
options through DOWN and UP keys. By pressing the MENU key,
you will activate the option viewed and you will return to the
configuration menu.
Time menu setup
Time menus allow setting a function duration. When you enter
into a time menu, the current setup value will be viewed; the
display mode depends on the current value:
• Times being lower than one minute will be viewed as follows:
each time you press UP key, current time value increases of
half a second; vice versa, each time you press the DOWN
key, current time value decreases of half a second.
• Times between 1 and 10 minutes will be viewed as follows:
each time you press UP key, current time value increases of
5 seconds; vice versa, each time you press the DOWN key,
current time value decreases of 5 seconds.
• Times being more than 10 minutes will be viewed as follows:
each time you press UP key, current time value increases of
half a minute; vice versa, each time you press the DOWN
key, current time value decreases of half a minute.
By holding down the UP key, you can quickly increase the time
value, up to reach the max. value allowed for this item. Vice
versa, by holding down the DOWN key, you can quickly decrease
the time value down to reach 0.0".
In some circumstances, setting the value to 0 means that the
relevant function is disabled, in this case, 'no' will appear instead
of 0.0".
By pressing on MENU you will confirm the displayed value and
you will return to the configuration menu.
Value menu setup
Value menus are similar to time menus; however, the setup value
can be any number.
By holding down UP or DOWN keys, the value will increase or
decrease slowly.

QUICK CONFIGURATION

This paragraph concerns a quick procedure to set the control unit
and set it at work immediately. We recommend following these
instructions, in order to check quickly the correct operation of
control unit, motor and accessories, and then changing the
configuration in case of any non-satisfactory parameter. Please
refer to the paragraph "Control unit configuration" for the item
position inside the menu, as well as for the available options for
each item.
1. Call up a default configuration (item dEF.).
Select AntE for a door-gate, select Scor for other
configurations (sliding, rolling, sectional, etc.).
2. In case there is no electric lock on the gate, set t.SEr,
t.ASE and t.CvE values to zero.
4. Set items StoP, Foto, CoSt and FC.En according to the safety
devices installed on the gate.
5. Start the self-learning cycle (item APPr).
This last operation will close the configuration menu and store set
up parameters.
Self-learning procedure
• In case the end of stroke or the obstacle sensor has been
enabled, the gate will be activated in closing direction until
the stop end or the closing end of stroke is reached.
• In case NEITHER the ends of stroke OR the obstacle sensor
have been enabled, be sure that the gate is completely
closed when the procedure is started up.
• The gate will be activated in opening direction until the stop
end or the opening end of stroke is reached.
• In case the sensors have not been enabled, or if you realize
that they do not signal the position to the control unit, you
must send a START command when the gate reaches its
max. opening position.
• The gate will be activated in closing direction until the stop
end or the closing end of stroke is reached.
• In case the sensors have not been enabled, or if you realize
that they do not signal the position to the control unit, you
must send a START command must be sent when the gate
reaches its fully closed position.
WARNING: if the function PHOTOCELL SHADOW ZONE is
active and all the working conditions are satisfied (limit switches
enabled and start function during the opening phase disabled),
the intervention of the photocell during the self-learning does not
open the gate; the control unit automatically sets the parameters
of the shadow zone in order to disable the photocell when the
gate passes in the position of its intervention.
29

Publicité

loading