DESCRIPTION OF THE CONTROL UNIT
The control unit City4 is an innovative V2 product that
guarantees a safe and reliable automation for single leaf swings,
sliding gates, sliding doors, etc
The City4 has been designed to realize a product that meets all
kind of requirements, with a highly versatile control unit that
satisfies all the necessary requirements for a functional and
efficient installation.
City4 is provided with a display that, not only makes
programming simple, but also allows a continuous monitoring of
the input statuses; in addition, thanks to a menu structure, the
working schedule and the operation logic can be set easily.
In compliance with the European standards concerning
electrical safety and electromagnetic compatibility
(EN 60335-1, EN 50081-1 and EN 50082-1) it has been
equipped with the low voltage circuit total electric insulation
(motors included) from the network voltage.
Other characteristics:
• Automatic control for the null current relay switch.
• Power adjustment with wave shutting.
• Obstacle detection by means of monitoring start
condenser voltage.
• Automatic learning of the operation time.
• Operation by means of mechanical ends of stroke
connected to the gearcase or connected in series to
the motor.
• Tests for safety devices (photocells, ribbons and triacs)
before each opening.
• Deactivation of safety inputs through the configuration
menu: no jumper is required for terminals concerning safety
devices that have not been installed, yet. You will only need
to disable this function from its relevant menu.
• ADI connector for connecting CL1, CL1+, LUX2, LUX2+,
WES-ADI,
INSTALLATION
Installation of control unit and safety devices must be carried out
with power disconnected.
POWER SUPPLY
The control unit must be fed by a 230V 50Hz (120V - 50/60Hz
for the model City4-120V) electric line, protected by a
differential magnetothermal switch complying with the law
provisions in force.
Connect power supply cables to terminals L and N of City4
control unit.
MOTOR
City4 control unit can control one alternate current
asynchronous motor. Max. total power is 700W.
Connect motor cables as follows:
• opening cable to terminal G3
• closing cable to terminal G5
• common return cable to terminal G4
WARNING:
In case it has not yet fitted, a start capacitor is required.
Connect the start capacitor between terminals G3 and G5.
WARNING (USING HYDRAULIC MOTORS):
• If using hydraulic motor, the following function could not
work properly: Soft start, Slowing down and Obstacle sensor.
In this case, such functions should be disabled from menu.
• Read carefully the working times self-learning procedure,
described in the paragraph "QUICK CONFIGURATION",
paying particular attention to the points where the procedure
to be followed in case of disabled obstacle sensor is described.
BLINKER
City4 control unit provides for a 230V 40W (120V – 40W for
model City4-120V) blinker equipped with intermittence inside.
Connect blinker cables to terminals G6 and G7 of the control
unit.
COURTESY LIGHTS
Thanks to the output COURTESY LIGHT the control unit City4
allows the connection of an electric appliance (e.g. courtesy light
or garden lights), controlled automatically or by means of the
special transmitter key.
The output COURTESY LIGHT is a simple N.O. contact with no
power supply.
Connect the cables to terminals G1 and G2.