Télécharger Imprimer la page

Important Remarks; Declaration Of Conformity; Technical Specifications - V2 SPA CITY4 Mode D'emploi

Centrale digitale universelle pour le controle d'un moteur a 230v/120v

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT REMARKS

For any installation problem please contact our Customer Service
at the number +39-0172.812411 operating Monday to Friday
from 8:30 to 12:30 and from 14:00 to 18:00.
V2 has the right to modify the product without previous
notice; it also declines any responsibility to damage or
injury to people or things caused by improper use or
wrong installation.
Please read this instruction manual very carefully
before installing and programming your City4 control unit.
• This instruction manual is only for qualified technicians,
who specialize in installations and automations.
• The contents of this instruction manual do not concern the
end user.
• Every programming and/or every maintenance service
should be done only by qualified technicians.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1 (Machinery safety. electrical equipment of
machines, part 1: general rules)
EN 12445
(Safe use of automated locking devices,
test methods)
EN 12453
(Safe use of automated locking devices,
requirements)
• The installer must provide for a device (es. magnetotermical
switch) ensuring the omnipolar sectioning of the equipment
from the power supply.
The standards require a separation of the contacts
of at least 3 mm in each pole (EN 60335-1).
• After making connections on the terminal board, use one
hose clamp to fix dangerous voltage wires near the terminal
board and another hose clamp to fix safety low voltage wires
used for accessories connection; this way, in case of
accidental detachment of a conducting wire, dangerous
voltage parts will not come into contact with safety low
voltage ones.
• The plastic case has an IP55 insulation; to connect flexible or
rigid pipes, use pipefittings having the same insulation level.
• Installation requires mechanical and electrical skills,
therefore it shall be carried out by qualified personnel only,
who can issue the Compliance Certificate concerning the
whole installation (EEC Machine Directive 2006/42/CEE,
Annex IIA).
• The automated vehicular gates shall comply with the
following rules: EN 13241-1, EN 12453, EN 12445 as well
as any local rule in force.
• Also the automation upstream electric system shall comply
with the laws and rules in force and be carried out
workmanlike.
• The door thrust force adjustment shall be measured
by means of a proper tool and adjusted according to
the max. limits, which EN 12453 allows.
• We recommend to make use of an emergency
button, to be installed by the automation (connected
to the control unit STOP input) so that the gate may
be immediately stopped in case of danger.
• Always remember to connect the earth according to
current standards (EN 60335-1, EN 60204-1).

DECLARATION OF CONFORMITY

V2 S.p.A. hereby declare that CITY4 products conform to the
essential requirements established in the following directives:
- 2004/108/CEE (EMC Directive in accordance with standards
EN 61000-6-2, EN 61000-6-3 + EN 50336)
- 2006/95/CEE (Low Voltage Directive in accordance with
standards EN 60335-1 + EN 60335-2-95 + EN 60335-2-97)
- 99/05/CEE (Radio Directive in accordance with standard
EN 301 489-3)
Racconigi, lì 28/01/2010
V2 S.p.A. legal representative
Cosimo De Falco

TECHNICAL SPECIFICATIONS

Power supply
Max motors load
Max accessories load 24V
Working temperature
Protection fuse
Dimensions
Weight
Protection
24
230VAC - 50/60 Hz (City4)
120VAC - 50/60Hz (City4-120V)
700W
10W
-20°C / +60°C
F1 = 5A (City4)
F1 = 8A (City4-120V)
195 x 145 x 80 mm
1200g
IP55