CONTROL UNIT CONFIGURATION

This paragraph concerns the step-by-step procedure to set all operation parameters of City4 control unit. You can either follow all
procedure steps and perform a complete control unit configuration or select and adjust interesting items only. As for both cases, you will
have to perform the right exit procedure through item FinE, in order to activate your new configuration.
City4 control unit provides for a self-learning procedure of working times; therefore, we recommend that you set up a standard
configuration first (see previous paragraph), then you carry out the self-learning and finally you change any unsatisfactory items.
Default value loading
The value of all menu items can be brought to a standard value (see final
recap table) by means of only one command. There are two sets of
values available:
AntE
Values for a two-leaf gate equipped with a lock.
SCor
Values for a one-leaf sliding gate without lock.
After loading default values, the other menu items can be scrolled and
each parameter can be changed; exit from default menu will cause the
automatic selection of the next item.
Opening time
The motor will be operated for the setup time in the opening phase;
in case there is an obstacle or the end of stroke operates, the control
unit can stop the opening phase before the relevant time expires.
Partial opening time (pedestrian access)
When the control unit receives a Start Pedestrian command, it will open
the gate only, for a shorter time. Max allowed time to be setup is t.AP.
Closing time
The motor will be operated for the setup time in the closing phase;
In case there is an obstacle or the end of stroke operates, the control
unit can stop the opening phase before the relevant time expires.
To avoid that the gate does not close completely, we recommend to
setup a longer time than t.AP opening time.