Motor power
This menu allows adjusting the motor power.
The displayed value is the percentage of max. motor power.
WARNING: In case an hydraulic motor is used, set value 100.
Start off
When the gate is standstill and it begins moving, the initial inertia must
be faced, therefore, if your gate is quite heavy, it could not move.
In case the SPUNTO (pickup) function is activated, for the first 2 seconds
of motion of each door, the control unit will ignore Pot value and it will
give motor the maximum power command in order to overcome the
gate inertia.
Soft start (slowed down)
In case this function is enabled, during the first seconds of motion of the
gate, the control unit will give motor a reduced power command, for a
softer start.
Slowing down time
In case this function is enabled, during the last seconds of motion, the
control unit will give motor a reduced power command, to avoid a
strong impact with the stop end. t.AP is the max. allowed time.
WARNING:
• In case the self-learning function of working times is NOT used, we
recommend disabling the slowing down function in order to measure
both opening and closing times, and to enable it again once the
setup has been carried out. The control unit will automatically
consider the working time delay caused by the slowing down.
• If partial opening time t.APP is shorter than t.AP, there will be no
slowing down during the pedestrian cycle opening.
Fast closing time after slowing down
If a slowing time other than 0 is set up, it could be likely that the gate
speed is not enough for the lock to fasten during the closing phase.
In case this function is enabled, once the slowing down phase is
finished, the control unit will give a normal speed command (that is to
say, with no slowing down) for the set up time, and then it will open
the gate for a second fraction, to avoid leaving the motor under stress.
WARNING: in case the gate has no electric lock, set the value 0.