Partial closing time (pedestrian access)
When the control unit receives a Start Pedestrian command, it will use
this time to close the gate. Max allowed time to be setup is t.CH1.
To avoid that the door does not close completely, we recommend to
setup a longer time than t.APP opening time.
Lock time
Before the opening phase begins, the control unit will energize the
electric lock in order to release it and enable the gate motion.
t.SEr time will fix the energizing time.
WARNING: in case the gate has no electric lock, set the value 0
('no' will appear on display).
Lock advance time
While the electric lock is energized, the gate will stay standstill for t.ASE
time, to make its release easier.
In case t.ASE is lower than t.SEr, the lock energizing will go on while
the gate will start moving.
WARNING: in case the gate has no electric lock, set the value 0.
Backlash time
It could be useful to give a closing command to motor, to help the
electric lock release.
The control unit controls the motor in reduced power in closing
direction for the setup time.
The backlash precedes the electric lock release. It is possible to reverse the
order by setting a lock advance time higher then the backlash one.
WARNING: in case the gate has no electric lock, set the value 0.
Pre-blinking time
Before any gate movement, blinker will be activated for t.PrE time, to
warn about the incoming motion.
31