t.LUC
the relay closes when a start or a pedestrian start control is given and opens after the set time. It works in the same way whit a
remote control on channel 4.
CiCL
the relay keeps closed during the whole opening/closing phase. In case of intervention of a remote control on channel 4, it keeps
closed for the time set by item T.LUC
AUS
auxiliary output with settable operation logic
In this last case, the COURTESY LIGHT output becomes an auxiliary output to which it is possible to link one of the following operation
logics:
tiM
TIMER the relay closes when a remote control arrives on channel 4 and opens after the set time
biSt
BISTABLE the relay changes each time a remote control arrives on channel 4
Mon
MONOSTABLE the relay keeps closed until a signal given by the remote control on channel 4 arrives.
Automatic closing
During the automatic operation, the control unit will automatically close
the gate when a set-up time expires.
The Start command, if enabled by St.PA menu, allows closing the gate
before the set up time expires.
In semi-automatic operation, that is to say, if the automatic closing
function is disabled by setting the value to zero ('no' will be displayed),
the gate can be closed through the start command only: in this case,
St.PA menu setup will be ignored.
If the control unit receives a Stop command when the gate is in pause, it
will automatically pass to the semi-automatic operation.
Closing after transit
During the automatic operation, the pause count down starts from the
set up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing as soon as transit through the
gate is completed, therefore, a time shorter than CH.AU is
generally used.
Ch.AU will be used when 'no' is set up.
As for semi-automatic operation, this function is not active.
Pause after transit
In order to let the gate open for the shortest possible time, it is possible
to stop the gate once the passage before the photocells is detected. If
the automatic working is enabled, the time of the pause is Ch.tr.
34
Courtesy lights
Thanks to the output COURTESY LIGHT
the control unit City4 allows the
connection of an electric appliance
(e.g. courtesy light or garden lights),
controlled automatically or by means
of the special transmitter key.