9.2 - ADDING OR REMOVING DEVICES
It is possible to add or remove devices at any time to the system: if devices are added, it is important to verify that these are perfectly compatible with
ARIA 200M/400M; for further details contact the Nice technical support service.
9.2.1 - Memorising additional devices
The recognition operation of the devices connected to the ECSbus and to the Stop input is usually car-
ried out during the installation phase; but if devices are added (or removed) subsequently, the following
procedure must be carried out:
01. On the control unit press and hold button P2 (Fig. 26) for at least 3 seconds then release it.
02. Wait a few seconds until the control unit has completed the device recognition procedure: led L2
switches off. If instead it flashes, it means that there is some error – see Chapter 10.
03. After adding or removing devices, the automation must be tested again (Par. 6.1).
9.3 - MEMORISING ADDITIONAL TRANSMITTERS
The control unit incorporates a radio receiver for ECCO5 transmitters (various models). The transmitters supplied are not memorised, therefore it is first
necessary to memorise the 1st transmitter (Par. 5.5); to memorise additional transmitters, it is possible to choose one of the procedures (Mode 1 or
Mode 2) indicated below. The control unit can memorise a total of 250 units: memorisation in Mode 1 occupies one unit of memory for each transmitter,
while the Mode 2 procedure occupies one unit of memory for each transmitter key.
Before carrying out the memorisation procedures, we recommend reading them and observing the indicated times.
9.3.1 - Mode 1 memorisation procedure
This procedure allows for simultaneously memorising all the transmitter keys, by automatically pairing them to the commands shown in Table 6.
A transmitter memorised in Mode 1 can control only a single automation.
TABLE 6
Keys
Paired command
T1
Step-by-step
T2
Partial open
T3
Open only
T4
Close only
Memorisation procedure
01. On the control unit (Fig. 28) press and hold key P1 for 3 seconds; when led L1 switches on, release the key.
02. Within 10 seconds from releasing it, press and hold for 3 seconds any key of the transmitter to be memorised (excluding key T5 - Fig. 27).
If the memorisation procedure was successful, led L1 (on the control unit) will flash 3 times.
03. To memorise other transmitters, repeat step 02 within the next 10 seconds otherwise the memorisation phase will terminate automatically.
9.3.2 - Mode 2 memorisation procedure
This procedure allows for memorising one key at a time, by pairing one of the desired commands shown in Table 7.
A transmitter memorised in Mode 2 can control multiple automations (for example: automation 1 controlled by key 1; automation 2 controlled
by key 2; and so forth)
No. of key
Paired command
presses
once
Step-by-step
twice
Pedestrian opening
3 times
Open only
4 times
Close only
5 times
Stop
6 times
Condominium open
7 times
High priority open
8 times
Pedestrian opening 2
9 times
Pedestrian opening 3
10 times
Open + lock automation
11 times
Close + lock automation
12 times
Lock automation
13 times
Release automation
9.3.3 - Memorisation procedure near the control unit with two transmitters (without using the control unit keys)
With this procedure a NEW transmitter is memorised using a second transmitter (OLD) already memorised and operating, without using the keys of
the control unit but drawing close to the latter.
During the procedure the NEW transmitter is memorised in the same way that the OLD transmitter was memorised (Mode 1 or Mode 2).
• Procedure with OLD transmitter memorised in Mode 1:
01. Draw near the control unit with the two transmitters:
02. On the NEW transmitter, press and hold any key for at least 8 seconds then release it.
03. On the OLD transmitter, press and hold any key to be copied for at least 2 seconds then release it.
04. On the OLD transmitter, press and hold any key to be copied for at least 2 seconds then release it.
05. On the OLD transmitter, press and hold any key to be copied for at least 2 seconds then release it.
27
TABLE 7
No. of flashes of led
L1 on the control
unit
1
2
3
4
5
6
7
8
9
10
11
12
13
wait 1 second between two successive steps.
LED
T5
T1
T2
T3
T4
Memorisation procedure
01. Before proceeding, it is necessary to cancel the memory of
the transmitter to be memorised – see Par. 9.4.
02. In Table 7, choose the command and the number of press-down
actions to be effected on the desired transmitter key.
03. On the control unit (Fig. 28) press and release key P1 for a
number of times corresponding to the chosen command (Table 5);
led L1 must emit a number of fast flashes corresponding to the
chosen command.
04. Within 10 seconds, press and hold for 2 seconds the key of the
transmitter to be memorised: if the memorisation was successful,
led L1 (on the control unit) will flash 3 times.
05. To memorise other transmitters, with the same command, repeat
step 03 within 10 seconds, otherwise the memorisation phase will
terminate automatically.