BFT LEO B CBB DL2 3 230 L02 Instructions D'installation page 29

Masquer les pouces Voir aussi pour LEO B CBB DL2 3 230 L02:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
Logic
Definition
Fixed code
FIXED CODE
Setting the
Protection
protection level
level
Serial mode
(Identifies how
SERIAL MODE
board is configured
in a BFT network
connection).
Address
ADDRESS
Configuration of
EXPI1 input on
input-output ex-
EXPI1
pansion board.
1-2
Configuration of
EXPI2 input
on input-output
EXPI2
expansion board.
1-3
INSTALLATION MANUAL
Cross out
Default
setting
used
Receiver is configured for operation in rolling-code mode.
0
Fixed-Code Clones are not accepted.
0
 
Receiver is configured for operation in fixed-code mode.
1
Fixed-Code Clones are accepted.
A - The password is not required to access the programming menus
B - Enables wireless memorizing of transmitters.
Operations in this mode are carried out near the control panel and do not require access:
- Press in sequence the hidden key and normal key (T1-T2-T3-T4) of a transmitter that has already been memo-
rized in standard mode via the radio menu.
- Press within 10 sec. the hidden key and normal key (T1-T2-T3-T4) of a transmitter to be memorized.
The receiver exits programming mode after 10 sec.: you can use this time to enter other new transmitters by
0
repeating the previous step.
C - Enables wireless automatic addition of clones.
Enables clones generated with the universal programmer and programmed Replays to be added to the receiver's
memory.
D - Enables wireless automatic addition of replays.
Enables programmed Replays to be added to the receiver's memory.
E - The board's parameters can be edited via the U-link network
A - You are prompted to enter the password to access the programming menus
1
The default password is 1234.
No change in behaviour of functions B - C - D - E from 0 logic setting
0
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
2
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled. No change in behaviour of functions D - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
3
B - Wireless memorizing of transmitters is disabled.
D - Wireless automatic addition of Replays is disabled.
No change in behaviour of functions C - E from 0 logic setting
A - You are prompted to enter the password to access the programming menus
The default password is 1234.
B - Wireless memorizing of transmitters is disabled.
C - Wireless automatic addition of clones is disabled.
4
D - Wireless automatic addition of Replays is disabled.
E - The option of editing the board's parameters via the U-link network is disabled.
Transmitters are memorized only using the relevant Radio menu.
IMPORTANT: This high level of security stops unwanted clones from gaining access and also stops radio interference,
if any.
0
Standard SLAVE: board receives and communicates commands/diagnostics/etc.
1
Standard MASTER: board sends activation commands (START, OPEN, CLOSE, PED, STOP) to other boards.
0
SLAVE opposite leaves in local network : the control unit is the slave in an opposite leaves network with no
 
2
smart module (fig.F)
MASTER opposite leaves in local network: the control unit is the master in an opposite leaves network with no
3
smart module (fig.F)
Identifies board address from 0 to 119 in a local BFT network connection.
0
 
[ ___ ]
(see U-LINK OPTIONAL MODULES section)
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
1
 
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the
11
movement stops.
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the
12
movement stops.
Input configured as Phot test safety, tested photocell. Input 3 (EXPI2) on input/output expansion board is switched
13
automatically to safety device test input, EXPFAULT1.
Input configured as Phot op test safety, tested photocell active only while opening. Input 3 (EXPI2) on input/
14
output expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Phot cl test safety, tested photocell active only while closing. Input 3 (EXPI2) on input/output
15
expansion board is switched automatically to safety device test input, EXPFAULT1
Input configured as Bar safety, tested safety edge. Input 3 (EXPI2) on input/output expansion board is switched
16
automatically to safety device test input, EXPFAULT1.
Input configured as safety Bar OP test, safety edge with inversion active only while opening, if while closing the
17
movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device
test input, EXPFAULT1.
Input configured as safety Bar CL test, safety edge with inversion active only while closing, if while opening the
18
movement stops. Input 3 (EXPI2) on input/output expansion board is switched automatically to safety device
test input, EXPFAULT1.
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
5
Input configured as Timer command.
0
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
11
Input configured as safety Bar OP, safety edge with inversion active only while opening, if while closing the movement stops.
12
Input configured as safety Bar CL, safety edge with inversion active only while closing, if while opening the movement stops.
LEO B CBB DL2 3 230 L02-LEO B CBB DL2 3 120 F02-LEO B CBB DL2 3 120 F02 PHOT USA16 - LEO B CBB DL2 3 230 SV
Optional extras
29

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Leo b cbb dl2 3 120 f02Leo b cbb dl2 3 120 f02 phot usa16Leo b cbb dl2 3 230 sv

Table des Matières