BFT LEO B CBB DL2 3 230 L02 Instructions D'installation page 28

Masquer les pouces Voir aussi pour LEO B CBB DL2 3 230 L02:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
Logic
Definition
Configuration
of safety input
SAFE 1
SAFE 1.
Configuration
of safety input
SAFE 2
SAFE 2.
Configuration
of safety input
SAFE 3
SAFE 3.
Configuration of
command input
IC 1
IC 1.
Configuration of
command input
IC 2
IC 2.
Configuration of
command input
IC 3
IC 3.
Configuration of
command input
IC 4
IC 4.
Configuration
of the 1st radio
1ch
channel command
Configuration
of the 2nd radio
2ch
channel command
Configuration
of the 3rd radio
3 ch
channel command
Configuration
of the 4th radio
4 ch
channel command
Configuration of
AUX 0 output.
AUX 0
20-21
AUX 3
(Setup for
LEO B CBB DL2
Configuration of
3 120 F02 PHOT
AUX 3 output.
26-37
USA16)
LEO B CBB DL2 3 120 F02
(only for sw versions
7.08)
28 - LEO B CBB DL2 3 230 L02-LEO B CBB DL2 3 120 F02-LEO B CBB DL2 3 120 F02 PHOT USA16 - LEO B CBB DL2 3 230 SV
INSTALLATION MANUAL
Cross out
Default
setting
used
0
(LEO B
CBB DL2
3 120
F02)
(LEO B
CBB DL2
3 230
L02)
(LEO B
CBB DL2
3 230
SV)
72
1
(LEO
B CBB
DL2 3
120 F02
PHOT
USA16)
Not
configu-
rable
6
74
2
77
0
61
4
62
 
2
64
3
65
0
9
2
5
6
 
0
0
Input configured as Phot (photocell).
1
Input configured as Phot test (tested photocell).
2
Input configured as Phot op (photocell active during opening only).
3
Input configured as Phot op test (tested photocell active during opening only).
4
Input configured as Phot cl (photocell active during closing only).
5
Input configured as Phot cl test (tested photocell active during closing only).
6
Input configured as Bar, safety edge.
7
Input configured as Bar, tested safety edge.
8
Input configured as Bar 8k2 (Inactive on SAFE 3).
9*
Input configured as Bar OP, safety edge with inversion active only while opening. If while closing, the movement stops.
Input configured as Bar OP TEST, safety edge tested with inversion active only while opening. If while closing,
10*
the movement stops.
Input configured as Bar OP 8k2, safety edge with inversion active only while opening. If while closing, the
11*
movement stops.
(Inactive on SAFE 3).
12*
Input configured as Bar CL, safety edge with inversion active only while closing. If while opening, the movement stops.
Input configured as Bar CL TEST, safety edge tested with inversion active only while closing. If while opening,
13*
the movement stops.
Input configured as Bar CL 8k2, safety edge with inversion active only while closing. If while opening, the
14*
movement stops.
(Inactive on SAFE 3).
0
Input configured as Start E.
1
Input configured as Start I.
2
Input configured as Open.
3
Input configured as Close.
4
Input configured as Ped.
5
Input configured as Timer.
6
Input configured as Timer Pedestrian.
0
Radio control configured as START E.
1
Radio control configured as Start I.
2
Radio control configured as Open.
3
Radio control configured as Close
4
Radio control configured as Ped
5
Radio control configured as STOP
6
Radio control configured as AUX0 **
7
Not used
8
Not used
9
Radio control configured as AUX3 **
10
Radio control configured as EXPO1 **
11
Radio control configured as EXPO2 **
0
Output configured as monostable Radio Channel.
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
4
Output configured as Stair Light
5
Output configured as Alarm
6
Output configured as Flashing light
7
Output configured as Latch
8
Output configured as Magnetic lock
9
Output configured as Maintenance
10
Output configured as Flashing Light and Maintenance.
11
Not used
12
Output configured as Antitampering
13
Output configured as Gate Status
14
Output configured as Bistable Radio Channel
15
Output configured as timed Radio Channel
Optional extras

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Leo b cbb dl2 3 120 f02Leo b cbb dl2 3 120 f02 phot usa16Leo b cbb dl2 3 230 sv

Table des Matières