TABLE "B" - LOGICS
(LOGIC)
Logic
Definition
Automatic Closing
TCA
Time
Fast closing
FAST CLS.
Step-by-step
STEP-BY-STEP
movement
MOVEMNT
Encoder
Encoder
Pre-alarm
PRE-ALARM
Deadman
HOLD-TO-RUN
Block pulses du-
IBL OPEN
ring opening
Block pulses
|IBL TCA
during TCA
Block pulses
IBL CLOSE
during closing
Open in other
OPEN IN OTHER
direction
DIRECT.
INSTALLATION MANUAL
Cross out
Default
setting
used
0
Logic not enabled
0
1
Switches automatic closing on
0
Logic not enabled
0
1
Closes 3 seconds after the photocells are cleared before waiting for the set TCA to elapse.
Inputs configured as
0
Start E, Start I, Ped oper-
ate with 4-step logic.
Inputs configured as
Start E, Start I, Ped op-
1
erate with 3-step logic.
Pulse during closing
reverses movement.
0
Inputs configured as
Start E, Start I, Ped op-
2
erate with 2-step logic.
Movement reverses with
each pulse.
Operation with encoder disabled
This setting fully disables the anti-
crush safety device, with serious
safety risks.
Install active safety edges on closing
2
and opening or switch to deadman
(LEO B
0
operation. (see Deadman logic)
CBB DL2
The slowing down spaces are an
3 120
estimate made through the gate
F02)
travel time.
(LEO
For greater precision on the slowing
B CBB
down point, set encoder = 1 or 2.
DL2 3
120 F02
Only for LEO B CBB DL2 3 230 SV,
PHOT
in this mode the motor can only
USA16)
operate at low speed.
(LEO B
Operation with encoder used as posi-
CBB DL2
tion sensor for acquiring slow-down
3 230
L02)
distances. - Gate detection locked
1
out. Manual setting of "opening force",
1
"closing force", "opening slow-down
(LEO B
force" and "closing slow-down force"
CBB
parameters.
DL2 3
2
230 SV)
LEO B CBB DL2 3
Automatic mode with encoder: slow-
120 F02
down and obstacle detection perfor-
med by means of encoder. Adjustment
(only for sw ver-
of obstacle detection sensitivity
sions 7.08)
(opening force, closing force, opening
LEO B CBB DL2 3 120
slow-down force, closing slow-down
F02 PHOT USA16
force parameters) (default setting).
(only for sw ver-
sions 8.08)
0
The flashing light comes on at the same time as the motor(s) start.
0
1
The flashing light comes on approx. 3 seconds before the motor(s) start.
0
Pulse operation.
Deadman mode.
Input 61 is configured as OPEN UP.
Input 62 is configured as CLOSE UP.
1
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
0
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, Deadman mode is
enabled which will stay active for 1 minute after the OPEN UP - CLOSE UP keys are released.
Input 61 is configured as OPEN UP.
2
Input 62 is configured as CLOSE UP.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during TCA pause.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during TCA pause.
0
Pulse from inputs configured as Start E, Start I, Ped has effect during closing.
0
1
Pulse from inputs configured as Start E, Start I, Ped has no effect during closing.
0
Standard operating mode (Fig.G Rif. 1).
0
1
Opens in other direction to standard operating mode (Fig. G Rif.2)
LEO B CBB DL2 3 230 L02-LEO B CBB DL2 3 120 F02-LEO B CBB DL2 3 120 F02 PHOT USA16 - LEO B CBB DL2 3 230 SV
Optional extras
step-by-step mov.
2 STEP
CLOSED
OPENS
DURING
CLOSING
OPEN
CLOSES
DURING
OPENING
AFTER STOP
OPENS
WARNING
WARNING: Check that the force of impact measured at the points
provided for by standard EN 12445 is lower than the value laid down
by standard EN 12453.
WARNING: Setting sensitivity incorrectly can result in damage
to property and injury to people and animals.
WARNING: safety devices are not enabled.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
3 STEP
4 STEP
OPENS
OPENS
STOPS
CLOSES
CLOSES
STOP + TCA STOP + TCA
OPENS
OPENS
27