Initialising all sensors
Command master to sensor
Character Character/Meaning
position
1
c
Response sensor to master
Character Character/Meaning
position
none
Example
master
c
transmits
sensor
responds
3964(R) protocol
In accordance with the 3964(R) protocol standard the reader implements the "trans-
mit data" function.
The following parameters apply to the data link layer (layer 2):
• Priority:
• Character delay time:
• Acknowledgement delay time:
• Attempts to connect:
• Number of repeats:
Comment
command character
Comment
sensor transmits no response
sensor is initialised
high
200 ms
3 s
6
6
57